摘要
对ZPW-2000A型无绝缘移频自动闭塞系统设备组成作了介绍。阐述了移频报警故障、红光带故障的判断和查找方法,以及如何区分室内外故障和室外故障的查找方法。
This paper introduced the composition of ZPW-2OOOA automatic block system with jointless shift frequency. It explained how to judge and pinpoint shift frequency warning fault and red-light strap trouble as well as how to differentiate the indoor troubles and outdoor troubles.
出处
《铁道通信信号》
2007年第6期15-16,共2页
Railway Signalling & Communication
关键词
轨道电路
故障
处理
Track circuit
Fault
Handling