期刊文献+

聚甲基丙烯酸羟乙酯水凝胶人工晶状体材料的合成与性能 被引量:4

Synthesis and Properties of Poly(hydroxyethyl methacrylate) Hydrogel for IOL Materials
下载PDF
导出
摘要 以甲基丙烯酸羟乙酯为原料,过硫酸铵/偏重亚硫酸钠为引发体系,二甲基丙烯酸三乙二醇酯为交联剂,采用溶液聚合法制备了聚甲基丙烯酸羟乙酯水凝胶(PHEMA)人工晶状体材料。系统考察了聚合反应时间、温度及引发剂和交联剂的用量等对该水凝胶材料机械强度、平衡水含量(EWC)的影响,并对PHEMA水凝胶的结构和光学性能进行了表征。实验结果表明,PHEMA水凝胶的最佳合成条件为:引发剂0.5wt%,交联剂1.0wt%,反应温度40℃,反应时间36h。在此条件下制备的PHEMA水凝胶的拉伸强度达到0.57MPa,邵氏A硬度为23.0,平衡含水量超过40%,透光率≥97%。 Poly (hydroxyethyl methacrylate) (PHEMA) hydrogel for intraocular lens (IOL) materials was synthesized by solution polymerization using 2-hydroxyethyl methacrylate (HEMA) as raw material, ammonium persulfate and sodium pyrosulfite (KPS/SMBS) as catalyst, and trietyleneglycole dimethacrylate (TEGDMA) as cross-linking additive. Effects of reaction time, temperature, dosage of catalyst and cross-linking additive on mechanical strength and the equilibrium water content (EWC) of the PHEMA hydrogel were systematically investigated and their structure and optical property were also characterized. The experimental results showed that the optimum conditions for preparing PHEMA hydrogel are: catalyst 0. 5wt %, cross-linking additive 1.0wt %, reaction temperature 40℃, reaction time 36 h. Under the optimum conditions, the tensile strength of PHEMA hydrogel prepared is as high as 0.57MPa, hardness of Shore A is 23.0, EWC is over 40%, and light transmittance is over 97%.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2007年第3期595-598,共4页 Journal of Biomedical Engineering
基金 华南理工大学"学生研究计划"项目
关键词 聚甲基丙烯酸2-羟乙酯 水凝胶 人工晶状体材料 合成 性能 Poly (hydroxyethyl methacrylate) (PHEMA) Hydrogel Intraocular lens (IOL) materials Synthesis Property
  • 相关文献

参考文献12

  • 1Hollick EJ,Spalton DJ,Ursell PG,et al.The effect of polymethylmethacrylate,silicone,and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery.Ophthalmology,1999; 106(1):49 被引量:1
  • 2Abela-Formanek C,Amon M,Schild G,et al.Uveal and capsular biocompatibility of hydrophilic acrylic,hydrophobic acrylic,and silicone intraocular lenses.Cataract Refract Surg,2002; 28(1):50 被引量:1
  • 3王桂琴,何炳林.硅凝胶软性人工晶状体表面特性及其生物相容性[J].离子交换与吸附,2000,16(5):472-478. 被引量:4
  • 4Jacqueline H,Coenraad J,Ralph V,et al.Hydrogels for an accommodating intraocular lens.An explorative study.Biomacromolecules,2003; 4(3):608 被引量:1
  • 5Eschbach,FO,Huang,SJ.Hydrophilic-hydrophobic binary systems of poly(2-hydroxyethyl methacrylate) and polycaprolactone.Part I:Synthesis and characterization,1994; 9(1):29 被引量:1
  • 6Lou X,Vijayasekaran S,Chirila TV,et al.Synthesis,physical characterization,and biological performance of sequential homointerpenetrating polymer network sponges based on poly(2-hydroxyethyl methacrylate).J Biomed Mater Res,1999; 47(3):404 被引量:1
  • 7Ferruti P,Grigolini M,Ranucci E.PHEMA hydrogels obtained by a novel low-heat curing procedure with a potential for In situ preparation.Macromol Bioscience,2004; 4(6):591 被引量:1
  • 8黎新明,崔英德,蔡立彬.共聚物水凝胶接触镜材料的研究[J].高分子材料科学与工程,2004,20(2):191-194. 被引量:15
  • 9Andreas G.Andreopoulos preparation of hydrophilic polymer networks by post-curing reaction.Journal of Applied Polymer Science,1992; 45(6):1005 被引量:1
  • 10郭建维,康正,崔亦华,易国斌,崔英德.NVP-HEMA-EMA三元共聚制备水凝胶及其性能研究[J].石油与天然气化工,2004,33(1):43-45. 被引量:5

二级参考文献21

共引文献20

同被引文献60

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...