摘要
通过分析高层建筑给水系统能耗构成,论证了减少剩余水头在给水节能中的重要作用,分析了减少剩余水头的各种措施,可得出给水系统中使用水泵并联给水方式节能效果更好,并探讨了变频给水的节能原理和方法,提出了相关参数选取的参考原则。
By the analysis of the energy consumption composition of water supply system for highrise building, the importance of reducing residual head in water supply energy-saving was demonstrated. All measures for reducing residual head were analyzed. It is concluded that the water supply mode with parallel water pumps in water supply system is more effective in energy-saving. The principle and methods of energy-saving for water supply with frequency conversion were discussed, and the reference principles for selection of relevant parameters were put forward.
出处
《中国给水排水》
CAS
CSCD
北大核心
2007年第10期92-96,共5页
China Water & Wastewater
关键词
高层建筑
给水系统
节能
变频调速
high-rise building
water supply system
energy-saving
frequency conversion speed regulation