摘要 目的:测试激光焊接铸造和锻造纯钛(TA2)及钛合金(TC4)疲劳强度和拉伸负荷,探讨一定条件下激光焊接后铸造和锻造钛试件的疲劳强度及临床应用的可行性。方法:将铸造和锻造纯钛及钛合金加工成一定规格的试件,进行激光焊接,焊后用疲劳试验机测得母材及焊件的疲劳强度,并进行断裂试件断口的扫描电镜分析,结果分别进行比较。结果:激光焊接铸造和锻造纯钛及钛合金试件的疲劳强度与对照组有统计学差异,激光焊接断口有气泡及断裂裂纹。结论:与母材相比,激光焊接铸造和锻造纯钛及钛合金试件的疲劳强度有统计学差异。 Objective: This study evaluated the fatigue strength of laser-welded wrought and cast titanium specimens fabricated from commercial pure titinium (TA2) and titanium alloy (TC4). Methods: TA2 and TC4 were milled or cast into a certain size and joined with laser welding. A fatigue testing machine was used to test tensile load and fatigue strength. The fatigue fracture surface was examined by scanning electron microscopy (SEM). Results: The rusults showed that the laser-welding decreased the fatigue strength of wrougth and cast titanium test specimen considerably compared to inact specimens. Fatigue strength of the original cast titanium made no difference from that of the wrought titanium. SEM examination showed that there were defects such as pore and cracks in the welding zone. Conclusion: The fatigue strength of the laser-welded wrought and cast titanium or titanium alloy were slightly lower than those of intact specimens
出处 《口腔颌面修复学杂志》 2007年第2期130-132,共3页 Chinese Journal of Prosthodontics
关键词 纯钛 钛合金 激光 激光焊接 疲劳强度 铸造 锻造 titanium pure titanium titanium alloy lasers laser welding fatigue strength cast wrought
  • 相关文献

参考文献5

二级参考文献20

  • 1Wang R R,J Prosthet Dent,1995年,74卷,5期,521页 被引量:1
  • 2Zavanelli R, Guilherme A, Pessanha G, et al. Corrosionfatigue of laser-repaired Commercially pure titanium and Ti-6Al-4VI alloy under different test environments [J]. Journal of oral Rehabiltation, 2004, 31 : 1029-1034 被引量:1
  • 3Hanselm W, Thierry D, Susanne S, et al. Mechanical and structural characteristics of commercially pure grade 2 Ti welds and solder joints [J]. Journal of materials science: materials in medicine, 2001, 12: 719-725 被引量:1
  • 4李明勇 马轩祥 李玉龙 等.口腔修复体疲劳寿命测试机的研制与标定(一)—仪器的研制[J].医疗卫生装备,2004,6:8-9. 被引量:2
  • 5Ameen K, Roxana S, Shuichi N, et al. Fatigue resistance of two implant/abutment joint designs [J]. J Prosthet Dent, 2002, 88(6):604-610. 被引量:1
  • 6Ameen K, Akihiko H, Shuichi N, et al. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system[J]. J Prosthet Dent, 2004, 91 (4): 326-332 被引量:1
  • 7Roman M, Steven K, Brien R, et al. Examination of the implant abutment interface after fatigue testing[J]. J Prosthet Dent, 2001, 85(3): 268-275 被引量:1
  • 8Murat C, Kvanc A, Haldun I, et al. Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant:influence of abutment design[J]. Clin. Oral lmpl Res, 2004, 15:459-465. 被引量:1
  • 9Ahmad M, Noriyuki W, Hidekazu T, et al. Deflection fatigue of Ti-6Al-7Nb, Co-Cr, and gold alloy cast clasps [J]. J Prosthet Dent, 2005, 93(2): 183-188. 被引量:1
  • 10Bates JF. Studies retated to the fracture of partial dentures flexural fatigue of cobalt-chromium alloy [J]. Br Dent J, 1965, 118:532-537. 被引量:1

共引文献2

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部