介绍了温度裂缝、干缩裂缝的性质,并对引起这些裂缝产生的原因进行了分析,同时从规范、设计、建设、施工等方面提出了温度裂缝的预防措施,从设置控制缝、灰缝钢筋、配筋带等方面论述了干缩裂缝的预防措施,以保证砌体结构的安全使用。
It introduces the nature of the temperature crack and the desiccation crack, analyzes the corresponding reasons, brings forward the precaution measures to temperature cracks from the aspects of the standard, design, building and construction etc, and discusses the precaution measures to the desiccation cracks from the aspects of control joints institution, bar in ash joint, reinforcement belt etc, which will assure the safe application of the bricking-up structure.
出处
《山西建筑》
2007年第13期139-140,共2页
Shanxi Architecture
关键词
砌体结构
温度裂缝
干缩裂缝
预防措施
bricking-up structure, temperature crack, desiccation crack, precaution measure