介绍了对桩基进行高应变动力试验与静载试验对比,找出两种试验误差的重要性,结合工程实例,对预应力管桩两种桩基检测结果进行了对比,以确保管桩工程质量,从而保证工程安全。
It introduces the comparison of high-reaction test and static load test of pile basement, finds out the importance of two testing inaccuracy. Combined with practical project, it compares the two checking results of prestressing force tube pile, in order to ensure the quality of tube pile quality and the safety of project.
出处
《山西建筑》
2007年第13期94-95,共2页
Shanxi Architecture
关键词
预应力管桩
桩基
工程质量
prestressing force tube pile, pile basement, project quality