改善核电机组启动阶段蒸汽发生器水质的措施 被引量:3

Means of Improving the Water Quality of Steam Generators of Nuclear Power Units in the Start-up Stage
下载PDF
导出
摘要 从核电厂运行控制和改善蒸汽发生器二回路水质的冲洗操作经验,分析了主给水泵启动,蒸汽发生器排污流量等因素对水质的影响。这些改善措施使机组启动满足了电厂运行技术规范书的要求,并达到了世界核营运者协会(WANO)规定的化学性能指标。 The main experiences in flushing manipulations operational control measures, for improving water quality in the steam generator' s secondary cycle, are epitomized from the point of view of operation and control of nuclear power plants, accompanied by an analysis of factors that influence SG's water quality like start-up of the principal feed pump and SG's blow-down. By proper improvements in operation and control,the unit's start-up can be made to meet the power plant' s required technical specifications of operation, and moreover meet the chemical indices, set by the World Association of Nuclear Operators.
出处 《发电设备》 2007年第3期209-213,共5页 Power Equipment
关键词 能源与动力工程 核电机组 启动 蒸汽发生器 水质 运行控制 energy and power engineering nuclear power unit start up steam generator water quality operation control
  • 相关文献

参考文献5

二级参考文献6

  • 1《广东大亚湾核电站岭澳核电站生产运行年鉴》编辑委员会.2002广东大亚湾核电站岭澳核电站生产运行年鉴[K].深圳,海天出版社,2003.72-76. 被引量:1
  • 2《广东大亚湾核电站岭澳核电站生产运行年鉴》编辑委员会.2003广东大亚湾核电站岭澳核电站生产运行年鉴[K].北京:原子能出版社,2003.261-262. 被引量:1
  • 3Benjamin L Dow Jr, James Benson. Keeping watch on steam generators[J]. NEI, 2001, (4): 22~23. 被引量:1
  • 4Green S J. Methods for preventing steam generator failure or degradation[J]. J Pres Ves & Piping, 1986,25(1~4) :359~391. 被引量:1
  • 5丁训慎.核电站蒸汽发生器传热管的腐蚀与防护[J].腐蚀与防护,2000,21(1):14-18. 被引量:35
  • 6陶钧.秦山核电站的化学控制[J].核电工程与技术,2001,14(2):30-35. 被引量:1