期刊文献+

U型管埋地换热器传热性能实验系统的研制 被引量:3

Development on an Experiment System of Thermal Property of the Ground Loop Heat Exchanger with U-bend Pipe
下载PDF
导出
摘要 从研究U型管换热器传热性能的目的出发建设了一套以热响应原理为理论基础的实验系统,介绍了实验设备与仪器仪表的选型、计算与安装。利用集散型计算机控制技术(DCS),把土壤源热泵实验系统建设成一个三级分布式计算机数据采集和控制(SCADA)系统。结果表明,该系统可以保证整个系统安全稳定运行,保证检测的数据可满足科研要求,具有一定的推广意义。 It was introduced that how to choose ,calculate and fix equipments and instruments of the experiment. A three stage distributed computer supervisory control and data acquisition(SCADA) system adopting DCS was designed. Adjust results show that this system can provide a reliable guarantee on safety operation, measure the data satisfying the request of science research. It is significant to extend to study and science research.
机构地区 东华大学
出处 《流体机械》 CSCD 北大核心 2007年第4期56-60,共5页 Fluid Machinery
关键词 埋地换热器 SCADA实验系统 可编程控制器 underground heat exchanger SCADA system PLC
  • 相关文献

参考文献7

二级参考文献14

  • 1孙同景.可编程序控制器应用基础[M].济南:山东科学技术出版社,1995.. 被引量:7
  • 2[1]SULATISKY M T, GVAN DER KAMP. Ground-source heat pumps in the candian prairies[J].ASHRAE Transactions, 1991,97(1):374-385. 被引量:1
  • 3[2]LARRY M, FETTKETHER. Geothermal system meets space heating requirements[J]. ASHRAE Journal,1992,98(3):43-45. 被引量:1
  • 4[3]CANE R L D, FORGAS D A. Modeling of ground-source heat pump performance[J]. ASHRAE Transaction, 1991,97(1):909-925. 被引量:1
  • 5[4]STEPHEN P, KAVANAUGH. Field tests for ground thermal properities-methods and impact on ground-source heat pump design[J].ASHRAE Transactions, 1992,98(2):607-615. 被引量:1
  • 6[5]BOSE J E. Soil and rock classification for the design of ground-coupled heat pump systems-field manual[R]. Epri CU-6600, Oklahoma: International Ground Source Heat Pumps Association, 1989. 被引量:1
  • 7[6]YU M Z, FANG Z H. The influence of soil freezing on heat transfer of geothermal heat exchangers[A].CSPE-JSPE-ASME,International Conference on Power Engineering[C]. Xi′an:TUP and Springer, 2001.1442-1449. 被引量:1
  • 8[7]KAVANAUGH S P, RAFFERTY K. Ground-source heat pumps: Design of geothermal systems for commercial and institutional buildings [M]. Atalanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, 1997. 被引量:1
  • 9[8]GU YIAN, O′NEAL DENNIS L. Development of an equivalent diameterr expression for vertical U-Tube used in ground-coupled heat pumps[J]. ASHRAE Transactions, 1998,104(2):347-355. 被引量:1
  • 10.北京亚控组态王6.0用户手册[Z].,2001.. 被引量:2

共引文献37

同被引文献14

  • 1Austin III,W.A. Development of an in-stiu system for measuring ground thermal properties[D]. Stillwater, Oklahoma: Oklahoma State University. 1998. 被引量:1
  • 2P Roth, A Georgiev, A Busso, et al. First in situ determination of ground and borehole thermal properties in Latin America[J]. America, Renewable Energy, 2004, 29: 1947-1963. 被引量:1
  • 3D Pahuda, B Mattheyb. Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ[J]. America,Energy and Buildings, 2001, 33: 503-507. 被引量:1
  • 4A Georgieva, A Bussob, P Roth. Shallow borehole heat exchanger: Response test and charging-discharging test with solar collectors[J]. America,Renewable Energy, 2006, 31 : 971-985. 被引量:1
  • 5S E A Gehlin, G Hellstrom, B Nordell. The influence of the thermosiphon effect on the thermal response test[J]. America, Renewable Energy, 2003, 28 : 2239-2254. 被引量:1
  • 6Arif Hepbasli, Ozay Akdemir, Ebru Hancioglu. Experimental study of a closed loop vertical ground source heat pump system[J]. America, Energy Conversion and Management, 2003, 44: 527-548. 被引量:1
  • 7朱汉宝,周亚素,撒世忠.U型管埋地换热器周围土壤传热性能实验研究[J].流体机械,2007,35(8):51-56. 被引量:13
  • 8朱瑞琪 张健明.热响应试验方法与机理.西部制冷空调与暖通,2004,24(2):1-3. 被引量:3
  • 9WARREN ADAM AUSTIN,III.Development of Aninsitu System for Measuring Ground Thermal Properties[D].Oklahoma State University Stillwater,Oklahoma.the Requirements for the Degree of MASTER,1998. 被引量:1
  • 10Chad A,Martin.Ground Thermal Conductivity Testing-Controlled Site Analysis ASHRAE[Z].Transctions:Ala. 被引量:1

引证文献3

二级引证文献19