期刊文献+

毛细管区带电泳分离大肠埃希菌部分因素的探讨 被引量:2

Investigation of some Influential Factors in the Determination of Escherichia Coli ATCC25922 by Capillary Zone Electrophoresis
下载PDF
导出
摘要 目的探讨毛细管区带电泳分离大肠埃希菌的有关影响因素。方法用毛细管区带电泳法对大肠埃希菌ATC-C25922进行了分离研究,分析缓冲液pH值、添加剂PEO分子量及浓度、电压和毛细管长度对分离的影响。结果缓冲液pH值、添加剂PEO分子量及浓度、电压和毛细管长度对毛细管区带电泳分离大肠埃希菌有较大影响,在优化的条件下,大肠埃希菌ATCC25922能达到很好的分离。结论调节贮存缓冲液TBE(4.5 mmoL/L Tris,4.5 mmoL/L硼酸,0.1mmoL/L EDTA)pH值至9.0,添加剂0.0125 g/dl PEO(Mr600 000),毛细管总长度50.2 cm,电压25 KV,毛细管区带电泳分离大肠埃希菌ATCC25922,分离时间20 min,峰形尖锐,效果最佳。 Objective To investigate some influential factors for determination of Escherichia coli ATCC25922 by capillary zone electrophoresis. Methods Escherichia coli ATCC25922 were determined by capillary zone electrophoresis. Buffer pH, additives PEO molecular weight and concentration,voltage,and capillary length were studied and optimized for fast and efficient separation. Results Buffer pH, additives PEO molecular weight and concentration, voltage,and capillary length could improve the separation profile,Escherichia coli ATCC25922 were well separated on best condition. Conclusion The stock buffer(4. 5 mmoL/L Tris,4.5 mmoL/L boric acid,and 0.1 mmoL/L EDTA)was adjusted to pH9.0,additives 0. 0125 g/dl PEO (Mr 600 000),capillary length 50. 2 cm,voltage 25 KV,migrating 20min,determining Escherichia coli ATCC25922 by capillary zone electrophoresis showed the peak focused into sharp and achieved extremely high efficiencies.
出处 《现代检验医学杂志》 CAS 2007年第2期63-65,共3页 Journal of Modern Laboratory Medicine
关键词 毛细管区带电泳 大肠埃希菌 缓冲液 capillary zone electrophoresis Escherichia coli buffer
  • 相关文献

参考文献8

  • 1Armstrong D W,Schneiderheinze J M.Rapid identification of the bacterial pathogens responsible for urinary tract infections using direct injection CE[J].Anal Chem,2000,72:4474-4476. 被引量:1
  • 2邓延倬 何金兰.高效毛细管电泳[M].北京:科学出版社,2000.100-115. 被引量:17
  • 3Shintani T,Yamada K,Torimora M.Optimization of a rapid sensitive identification system for Salmonella enteritidis by capillary electrophoresis with laser-induced fluorescence[J].FEMS Microbiol Lett,2002,210:245-249. 被引量:1
  • 4Gird M,Armstrong D W.Monitoring the immigration behavior of living microorganisms in capillary electrophoresis using laser-induced fluorescence detection with a charge-coupled device imaging system[J].Electrophoresis,2002,23:2048-2056. 被引量:1
  • 5祝松,何进,喻子牛.毛细管电泳在细菌分离分析中的应用[J].微生物学通报,2005,32(3):125-128. 被引量:4
  • 6Schneiderheinze J M,Armstrong D W,Schulte G,et al.High efficiency separation of microbial aggregates using capillary electrophoresis[J].FEMS Microbiol Lett,2000,189:39-44. 被引量:1
  • 7Meera J esai,Daniel W Armstrong.Separation identification and characterization of microorganisms by capillary electrophoresis[J].Microbiology and Molecularbiology Reviews,2003,67:38-51. 被引量:1
  • 8Shen Y,Berger S J,Smith R D.Capillary isoelectric focusing of yeast cells[J].Anal Chem,2000,72:4603-4607. 被引量:1

二级参考文献15

  • 1Mehrishi J N, Bauer J. Electrophoresis, 2002, 23:1984 - 1994. 被引量:1
  • 2Kremser L, Blaas D, Kenndler E. Electrophoresis, 2004, 25:2282 - 2291. 被引量:1
  • 3Desai M, Armstrong D W. Microbiol Mol Biol R, 2003, 67:38 - 51. 被引量:1
  • 4Pfetsch A, Welsch T. Fresen J Anal Chem, 1997, 359:198 - 201. 被引量:1
  • 5Glynn J R, Belongia B M, Arnold R G, et al. Appl Environ Microbiol, 1998, 64:2572 - 2577. 被引量:1
  • 6Torimura M, Ito S, Kano K, et al. J Chromatogr B, 1999, 721:31 - 37. 被引量:1
  • 7Dai D S, Chen Y, Qi L, et al. Electrophoresis, 2003, 24:3219 - 3223. 被引量:1
  • 8Armstrong D W, Schulte G, Schneiderheinze J M, et al. Anal Chem, 1999, 71:5465 - 5469. 被引量:1
  • 9Schneiderheinze J M, Armstrong D W, Schulte G, et al. FEMS Microbiol Lett, 2000, 189:39 - 44. 被引量:1
  • 10Armstrong D W, Schneiderheinze J M. Anal Chem, 2000, 72:4474 - 4476. 被引量:1

共引文献19

同被引文献54

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部