摘要 目的:探讨16层螺旋CT结肠成像(CTcolonography,CTC)技术在结肠疾病检出中的临床应用价值。方法:回顾性分析31例临床可疑结肠疾病患者的CTC检查结果并与纤维结肠镜、病理检查结果进行对照,计算CTC对结肠疾病诊断的敏感度、特异度及准确度。结果:CTC对结肠癌的检出率与纤维结肠镜相同,敏感度、特异度及准确度均达100%、100%、100%。CTC检查对直径≥10 mm,5.0~9.9 mm和<5 mm的息肉诊断的敏感度、特异度及准确度分别为100%、100%、100%,94.1%、100%、96.6%和75%、100%、93.1%。结论:CTC是一种无创伤性的影像学检查方法,对结肠疾病,尤其是结肠肿瘤、息肉诊断的敏感度、特异度及准确度均较高,可作为纤维结肠镜有价值的补充检查手段。 Objective: To evaluate the clinical value of 16 slices CT colonography(CTC) in the diseases of colon. Methods: In 31 consecutive patients, CTC and colonoscopy were performed. CTC findings were compared with those of colonoscopy and histopathology, which were the standard. The sensitivity, specifici- ty and accuracy of CTC for detection of colorectal diseases were calculated. Results: The sensitivity, specificity and accuracy of CTC for detection of colorectal cancer were the same as colonoscopy. The sensitivity, specificity and accuracy of CTC for detection of colorectal polyps of 10mm or larger, 5.0 ~9.9 mm, and smaller than 5mm were 100%, 100%, 100%, 94.1%, 100%, 96.6% and 75%, 100%, 93.1%, respectively. Conclusion: As a non-invasively diagnostic imaging, CTC has superior sensitivity, specificity and accuracy in detection of colorectal diseases, such as colorectal cancer and polyps, and can be used as an alternative to colonoscopy.
出处 《天津医科大学学报》 2007年第1期55-57,共3页 Journal of Tianjin Medical University
关键词 螺旋CT 结肠成像 结肠癌 结肠息肉 Spiral computed tomography Colonography Colorectal cancer Colorectal polyp
  • 相关文献

参考文献8

二级参考文献29

  • 1Johnson CD, Daehman AH. CT eolonography: the next colon screening examination? . Radiology, 2000, 216(2) :331-341. 被引量:1
  • 2Gazelle GS, Gaa J, Saini S, et al. Staging of colon carcinoma using water enema CT. J Comput Assist Tomngr, 1995, 19(1) :87-91. 被引量:1
  • 3Harvey CJ, Amin Z, Hare CM, et al. Helical CT pneumocolon to assess colonic tumors : radiologic - pathologic correlation. AIR, 1998, 170(6) : 1439-1443. 被引量:1
  • 4Hara AK, Johnson CD, Reed JE, et al. Detection of colorectal polyps by computed tomographic colography: feasibility of a novel technique. Gastroenterology, 1996, 110(1) : 284-290. 被引量:1
  • 5Hara AK, Johnson CD. MacCarty RL. et al. CT colonography:single versus multidetector row imaging. Radiology. 2001. 219(2) :461-465. 被引量:1
  • 6Hara AK, Johnson CD. Reducing data size and radiation does for CT colonography. AJR, 1997, 168(5) : 1181-1184. 被引量:1
  • 7Van Gelder RE. Venema HW, Serlie lWO, et al. CT colonography at different radiation dose levels: feasibility of dose reduction. Radiology, 2002. 224(1) :25-33. 被引量:1
  • 8Rubin GD, Beaulieu CF, Argiro V, et al. Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology, 1996, 199(2) : 321-330. 被引量:1
  • 9McFarland EG, Brink JA, Loh J, et al. Visualization of colorectal polyps with spiral CT colorgraphy? Evaluattion of processing parameters with perspeetive volume rendering.Radiology, 1997, 205(3) :701-707. 被引量:1
  • 10Mages GB, lornoza J. Computed tomography of colon carcinoma. AJR, 1980, 135(1) '.43-46. 被引量:1

共引文献187

同被引文献9

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部