期刊文献+

一种确定角膜屈光术后人工晶体屈光度的新方法 被引量:4

New method of calculating IOL power after excimer laser photorefract keratectomy
下载PDF
导出
摘要 提出了采用人工晶体(IOL)屈光度计算公式与光线追迹相结合的方法来预算准分子激光近视屈光矫正术后白内障术眼所需植入人工晶体(单焦点后房型)的屈光度。首先利用SRK-T计算公式根据角膜屈光术前的角膜测量参数确定人工晶体的植入位置,然后利用术后的角膜切削区光学参数,通过光线追迹的方法给出所需植入人工晶体的屈光度值。以Hwey-Lan Liou眼模型的角膜光学参数为基础,取眼轴长度为27mm,当近视屈光矫正度从3D到9D变化时,所需植入的人工晶体屈光度从16.99D增大到25.98D,表征该计算方法误差的Do与DN差值从0.12D增大到0.63D,均值为0.36D,与Jaime Aramberri计算法所获得的临床数据结果0.43D相当。该计算方法简单,准确。 A method of calculating Intraocular Lens (IOL) power (monofocal posterior chamber IOLs) after excimer laser photorefract keratectomy through theoretical IOL power calculation formula and ray tracing is proposed. First, with the corneal parameters which are obtained before refractive surgery, the position of effective lens is calculated by the standard SRK-T formula. And then with the optic parameters of cornea ablation zone, the power oflOL is calculated by ray tracing method. Based on the corneal optic parameters of Hwey-Lan Liou eye model, setting the axial length is 27mm, the IOL power increases from 16.99D to 25.98D when the corneal correction power varies from 3D to 9D, and the D-value of Do and DN which attributes the accuracy of the method calculating IOLs power varies from 0.12D to 0.63D, the mean value is 0.36D which is equal to Jaime Aramberri's clinical data result of 0.43D.
出处 《光电工程》 EI CAS CSCD 北大核心 2007年第4期55-59,共5页 Opto-Electronic Engineering
关键词 准分子激光 屈光矫正度 人工晶体 光线追迹 角膜切削区 Excimer laser Correction power Intraocular lens Ray tracing Cornea ablation zone
  • 相关文献

参考文献12

  • 1ARGENTO C,COSENTINO M J,BADOZA D.Intraocular lens power calculation after refractive surgery[J].J Cataract Refract Surg,2003,29:1346-1351. 被引量:1
  • 2ZALDIVER R,SHULTZ M C,DAVIDORF J M,et al.Intraocular lens power calculation in patients with extreme myopia[J].J Cataract Refract Surg,2000,26:668-674. 被引量:1
  • 3OLSEN T.Sources of error in intraocular lens power calculation[J].J Cataract Refract Surg,1992,18:125-129. 被引量:1
  • 4MACLAREN R E,SAGOO M S,RESTORI M,et al.Biometry accuracy using zero and negative-powered intraocular lenses[J].J Cataract Refract Surg,2005,31(2):280-290. 被引量:1
  • 5UCHIO E,OHNO S,KUSAKAWA T.Spherical aberration and glare disability with intraocular lenses of different optical design[J].J Cataract Refract Surg,1995,21(6):690-696. 被引量:1
  • 6刘永基,王肇圻,方志良,母国光.人眼模型中各折射面对人眼像差的贡献[J].光子学报,2005,34(10):1554-1556. 被引量:6
  • 7LIOU H L,BRENNAN N A.Anatomically accurate,finite model eye for optical modeling[J].J.Opt.Soc.Am.A,1997,14(8):1684-1695. 被引量:1
  • 8MUNNERLYN C R,KOONS S J,MARSHALL J.Photorefractive keratectomy:a technique for laser refractive surgery[J].J RefractSurg,1988,14:46-52. 被引量:1
  • 9JIMENEZ J R,ANERA R G,del BARCO L J.Effects on vision of approximations of the corneal-ablation profile during refractive surgery[J].Appl Opt,2005,40:2200-2205. 被引量:1
  • 10江海河,余吟山,陆志贤,周海.近视眼激光角膜切除术原理及控制方法[J].激光生物学报,1998,7(4):249-253. 被引量:21

二级参考文献9

共引文献23

同被引文献50

  • 1Feiz V,Mannis M J,Garcia-Ferrer F,et al.Tntraccular lens power calculation after laser in situ keratomileusis for myopia and hyperopia:a standardized approach.Cornea,2001,20:792-797. 被引量:1
  • 2美国眼科学会编写,陈跃国译.屈光手术学.北京:北京科学技术出版社,2006:175-178. 被引量:1
  • 3Feiz V, Mannis MJ, Garcia - Ferrer F, et al. Tntraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia: a standardized approach .Cornea, 2001, 20 (8): 792 - 797. 被引量:1
  • 4屈光手术学/美国眼科学会编写,陈跃国.译.北京:北京科学技术出版社,2006.8:175-178. 被引量:1
  • 5Kalyani SD, Alisa K, John GL, et al. Intraocular lens power calculation after corneal refractive surgery. Current Opt Ophthalmol, 2008, 19:357-362. 被引量:1
  • 6Tang M, Chen A, Li Y, et al. Corneal power measurement with Fourier-domain optical coherence tomography. J Cataract Refract Surg, 2010, 36:2115-2122. 被引量:1
  • 7Wang L, Mahmoud AM, Anderson BL, et al. Total corneal power estimation: ray tracing method versus gaussian optics formula. Invest Ophthalmol Vis Sci ,2011,5:1716-1722. 被引量:1
  • 8Holladay .IT, Van GS, Ting AC, et al. Silicone intraocular lens power vs temperature. Am J Ophthalmol, 1989, 107:428-429. 被引量:1
  • 9Savini G, Barboni P, Profasio V, et al. Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery. J Cataract Refrace Surg, 2008, 34: 809- 813. 被引量:1
  • 10McCarthy M, Gavanski GM, Paton KE, et al. Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology, 2011, 118: 940 -944. 被引量:1