摘要 采用膜混凝反应器(MCR)对滦河原水进行中试研究,重点考察了对污染物的去除效果、膜污染及清洗方式。结果表明:MCR工艺的出水水质符合《城市供水水质标准》(CJ/T 206—2005)的要求;在高温、高藻期投加4 mg/L三氯化铁后,对CODMn的去除率为44.6%,若同时投加2mg/L的有效氯,则可使对CODMn的去除率提高到53%,且进水水质波动较大时出水水质仍保持稳定;该工艺对浊度、细菌有很好的去除效果;当膜在较高通量下运行时,采用化学在线清洗(即EFM操作)可有效清除膜污染物质,及时恢复膜的过滤性能。 A pilot study on the treatment of Luanhe River water was conducted by using membrane coagulation reactor (MCR). The effects of pollutants removal, membrane fouling and cleaning methods were studied. The experimental results show that the treated water by MCR conforms to the requirements of Water Quality Standard for Urban Water Supply ( CJ/T 206 - 2005 ) issued by the Ministry of Construction. In the period of high temperature and algae, the CODMn removal rate is 44.6% at FeCl3 dosage of 4 mg/L, and increases to 53% when the effective chlorine of 2 mg,/L is added at the same time. And the treated water quality still keeps steady when the inlet water quality fluctuates largely. The turbidity and bacteria can be removed effectively by MCR. Enhanced flux maintenance (EFM) is an important method to decrease the membrane fouling under the condition of higher flux, which can restore the performance of membrane in time.
出处 《中国给水排水》 CAS CSCD 北大核心 2007年第7期23-27,共5页 China Water & Wastewater
基金 天津市科技创新专项基金资助项目(05FZZDSH00500)
关键词 膜混凝反应器 滦河水 膜污染 EFM membrane coagulation reactor (MCR) Luanhe River water membrane fouling enhanced flux maintenance
  • 相关文献

参考文献7

二级参考文献11

  • 1[1]Kishino H,Ishida H,et al.Domestic wastewater reuse using a submerged membrane bioreactor[J].Desalination,1996,106(16):115-119. 被引量:1
  • 2Thomas Lebeau, Claire Lelie vre, et al. Immersedmembrane filtration for the production of drinking water:combination with PAC for NOM and SOCs removal[J].Desalination, 1998,117(1~3):219-231. 被引量:1
  • 3Thomas Haider, Regina Sommer, et al. Genotoxic response of Austrian groundwater samples treated under standardized UV (254nm)-disinfection conditions in a combination of three different bioassays[J].Wat Res, 2002,36(1):25-32. 被引量:1
  • 4叶婴齐,工业用水处理技术,1995年 被引量:1
  • 5Xiao yan Li,Hiu Ping Chu.Membrane bioreactor for the drinking water treatment of polluted surface water supplies[J].Wat Res,2003,37(19):4781-4791. 被引量:1
  • 6国家环保局《水和废水监测方法》编委会.水和废水监测分析方法[M](第4版)[M].北京:中国环境科学出版社,2002.99-100,224-226,279-280. 被引量:1
  • 7A L Lim,Renbi Bai.Membrane fouling and cleaning in microfiltration of activated sludge wastewater[J].Journal of Membrane Science,2003,216:279-290. 被引量:1
  • 8刘忠洲,续曙光,李锁定.微滤、超滤过程中的膜污染与清洗[J].水处理技术,1997,23(4):187-193. 被引量:151
  • 9罗虹,顾平,杨造燕.投加粉末活性炭对膜阻力的影响研究[J].中国给水排水,2001,17(2):1-4. 被引量:38
  • 10陈尧,王向东.紫外线消毒技术在污水处理中的应用[J].重庆环境科学,2001,23(3):49-51. 被引量:19

共引文献41

同被引文献81

引证文献3

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部