热泵负荷调节中的两类模糊关系

TWO KINDS OF FUZZY RELATIONSHIPS IN LOAD ADJUSTMENT OF HEAT PUMP SYSTEM
下载PDF
导出
摘要 为了解决热泵系统输出能量和用户需求能量之间的动态平衡问题,合理的调节策略是必不可少的,本文对此进行了初步的尝试。在本文中,作者针对供需匹配效果较好的热泵运行数据进行了模糊聚类研究,并编程计算得出了环境温度和热泵供水温度以及环境温度和热泵系统COP之间的模糊关系,利用这一关系可以方便地确定它们之间的隶属函数, 为制定热泵系统的能量匹配控制策略奠定了基础. In order to match the output capacity of a heat pump system with the actual load requirement, some reasonable control strategies should be studied. Firstly, basing on some experimental data of the heat pump whose output capacity can match the load requirement well, the fuzzy clustering research is carried out. Two sorts' fuzzy relationships are presented: one of them is about the environment temperature and water temperature at the heat pump outlet, and the other is about the environment temperature and coefficient of performance (COP) of the heat pump. Secondly, the two relationships are used to build the membership functions among four parameters. They are a base to decide control strategies of energy matching.
作者 邹瑾 张天瑾
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2006年第3期379-381,共3页 Journal of Engineering Thermophysics
关键词 热泵 负荷调节 模糊聚类 控制策略 heat pump load adjustment fuzzy clustering control strategy
  • 相关文献

参考文献4

  • 1钱祥生编著..系统的建模与响应[M].北京:机械工业出版社,1990:168.
  • 2王骥程.过程动态模型.杭州:浙江大学出版社,1992.95-112 被引量:2
  • 3Borisov A N,Hab,Pavlov V A.Prediction of a Continuous Function With the Aid of Neural Networks.Automatic Control and Computer Sciences,1995,29(5):39-50 被引量:1
  • 4Hornid K.Multilayer Feedforward Networks are Universal Approximators.Neural Networks,1989,2(5):359-366 被引量:1

共引文献1