摘要 目的评价多层螺旋CT灌注扫描成像技术在脑肿瘤中的应用价值。资料与方法43例脑肿瘤患者于术前1周及术后出院时行常规CT扫描、CT灌注成像及增强扫描。数据应用CT工作站Perfusion3软件分析,获得脑血流量(CBF)图、血容量(CBV)图、对比剂平均通过时间(MTT)图和表面渗透性(PS)图。结果所有灌注图像均可清晰地显示肿瘤的大小与轮廓且能定量测定肿瘤组织的灌注状态。结论多层CT灌注成像为在体观察脑肿瘤血流状态及肿瘤血管功能提供了一种新的方法,对研究脑肿瘤的生物学特性,鉴别诊断及预后判断有一定的价值。 Objective To evaluate the application value of multislice CT perfusion imaging in brain tumors. Materials and Methods 43 patients with brain tumor were performed with conventional CT, CT perfusion and enhanced CT, CBF,CBV, MTT and PS were obtained by ADW4.2 workstation and were also analyzed. Results All functional maps could clearly display the turamors and measured perfusion status quantitatively. Conclusion Multi-slice CT perfusion provides a new method in evaluation of cerebral perfusion, function of tumor vessel, and is valuable in differential diagnosis and predicting prognosis of brain tumor.
出处 《临床放射学杂志》 CSCD 北大核心 2007年第3期227-230,共4页 Journal of Clinical Radiology
关键词 脑肿瘤 灌注成像 多层螺旋CT Brain tumor Perfusion imaging Multi-slice CT
  • 相关文献

参考文献15

  • 1Latchaw RE,Yonas H,Hunter GJ,et al.Recommendation for perfusion imaging in cerebral ischemia.Stroke,2003,34:1084 被引量:1
  • 2Eastwood JD,Provenzale JM.Cerebral blood flow,blood volume,and vascular permeability of cerebralglioma assessed with dynamic CT perfusion imaging.Neuroradiology,2003,45:373 被引量:1
  • 3Sobol WT,Curé JK.Can in vivo assessment of tissue hemodynamics with dynamic contrast-enhanced CT be used in the diagnosis of tumors and monitoring of cancer therapy outcomes? Radiology,2004,232:631 被引量:1
  • 4Roberts HC,Roberts TPL,Smith WS,et al.Multisection dynamic CT perfusion for acute cerebral ischemia:"The Toggling-Table" technique.AJNR,2001,22:1077 被引量:1
  • 5Wintermark M,Philippe J,Nabavi T.Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable Xenon CT:a validation study.AJNR,2001,22:905 被引量:1
  • 6Cenic A,Nabavi DG.A CT method to measure hemodynamics in brain tumors:validation and application of cerebral blood flow maps.AJNR,2000,21:462 被引量:1
  • 7Nabavi DG,Cenic A,Henderson S,et al.Perfusion mapping using computed tomography allows accurate prediction of cerebral infarction in experimential brain ischemia.Stroke,2001,32:175 被引量:1
  • 8Li CY,Shan S,Huang Q,et al.Initial stages of tumor cell induced angiogenesis:evaluation via skin window chambers in rodent models.J Natl Cancer Inst,2000,92:143 被引量:1
  • 9Hoeffner EG,Jain R,Shah GV,et al.Cerebral perfusion CT:technique and clinical applications.Radiology,2004,231:632 被引量:1
  • 10Jackson A,Kasssner A,Annesley-Wilhams D,etal.Abnormalities in the recirculation phase of contrast agent bolus passage in cerebral gliomas:Comparison with relative blood volume and tumor grade.Am J Neuroradiol,2002,23:7 被引量:1

二级参考文献17

  • 1Law M,Zagzag D,Golfinos JG,Knopp EA,Johnson G.Dynamic Contrast-Enhanced Perfusion MR Imaging Measurements of Endothelial Permeability: Differentiation between Atypical and Typical Meningiomas[J].中国神经肿瘤杂志,2003,1(3):149-149. 被引量:10
  • 2张菁,漆剑频,陈浪,黄文华.多层螺旋CT灌注成像对脑肿瘤血管通透性的研究[J].临床放射学杂志,2004,23(8):655-658. 被引量:20
  • 3Yeung WT, Lee TY, Del Maestro RF, et al. Effect of steroids on iopamidol blood-brain transfer constant and plasma volume in brain tumors measured with X-ray computed tomography. J Neurooncol, 1994,18:53 被引量:1
  • 4Ford J, Miles K, Hayball M, et al. A simplified method for measurement of blood-brain barrier permeability using CT: preliminary results and the effect of RMP-7. In: Faulkner K et al. editors. Quantitative imaging in oncology. London: British Institute of Radiology, 1 被引量:1
  • 5Miles KA, Hayball MP, Dixon AK. Color perfusion imaging: a new application of computed tomography. Lancet, 1991, 337:643 被引量:1
  • 6Hamberg LM, Hunter GJ, Halpern EF, et al. Quantitative high resolution measurement of cerebral vascular physiology with slip-ring CT.AJNR, 1996, 17:639 被引量:1
  • 7Tereda T, Nambu K, Hyotani G, et al. Cerebral blood flow: a method for quantitative measurement of cerebral vascular permeability using Xray CT and iodinated contrast medium. Neuroradiology, 1992, 34:290 被引量:1
  • 8Cenic A, Nabavi DG, Graen RA, et al. Dynamic CT measurement of cerebral blood flow: a validation study. AJNR 1999, 20:63 被引量:1
  • 9Nabavi DG, Cenic A, Dool J, et al. Quantitative assessment of cerebral hemodynamic using CT: Stability, accuracy, and precision studies in dogs. J Comput Assist Tomogra, 1999, 23:506 被引量:1
  • 10Lee TY, Nabavi DG, Graen RA, et al. Validation of cerebral blood flow maps from contrast-enhanced cine CT scanning: comparison of infarct size from TTC staining and blood flow threshold in a rabbit focal cerebral ischemia model. Radiology, 2000, 213:1305 被引量:1