1010例乙型肝炎病毒血清标志物检测结果分析 被引量:13

Analysis of serological markers of HBV in 1 010 cases
下载PDF
导出
摘要 目的 分析用化学发光微粒子免疫分析(CMIA)技术检测的乙肝两对半的模式特征。方法 用Architect i2000 SR全自动化学发光免疫分析仪对1010例血清标本进行乙肝两对半的定量检测,对于检测发现的少见模式(“1235”、“1245”、“1345”、“12345”)的38例标本再用ELISA法检测作对比分析。结果 CMIA法定量检测结果共15种模式,常见模式以“145”、“135”、“245”、“25”、“2”及全阴为主。ELISA法检测结果:少见模式中的“1345”主要表现为“145”;“1245”模式主要表现为“145”、“245”;“1235”模式主要表现为“135”;“12345”模式共2例,均表现为“15”。结论 乙肝两对半表现模式较为复杂,CMIA技术检测乙肝两对半的灵敏度、速度和自动化程度均较高。是目前临床检查乙肝两对半的较好方法。 Objective To analyze the modes of HBV serologic markers by chemiluminescent microparticle immunoassay(CMIA)technique. Methods HBV markers in the serum samples from 1 010 patients were quantitated by Abbott Architect i2 000SR, then 38 samples were selected from results (modes "1235","1245","1345","12345") randomly,and ELISA was applied to make a contrast. Resuits There were 15 different modes by CMIA. The"145","135","245","25","2" and five markers completely negative mode was predominant modes. Results by ELISA: the mode"145"was predominant in"1345" mode;the modes"145","245"were predominant in"1245"mode;the mode"135"was predominant in"1235" mode;the mode"12345"represented "15". Conclusion There are complex manifestation in the patients serological markers with HBV infection. The sensitivity, speed, automatism degree are higher in detecting HBV serologic markers by CMIA,and CMIA is a preferably technique in detecting HBV serologic markers at present.
出处 《国际检验医学杂志》 CAS 2007年第2期119-121,共3页 International Journal of Laboratory Medicine
关键词 DNA 病毒 肝炎病毒 乙型 肝炎e抗原 乙型 肝炎表面抗原 乙型 化学发光测定法 酶联免疫吸附测定 DNA,viral Hepatitis B virus Hepatitis B e antigens Hepatitis B surface antigens Chemilumineseent measurements Enzyme-linked immunosorbent assay
  • 相关文献

参考文献4

二级参考文献16

共引文献180

同被引文献75

引证文献13

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部