摘要
解决塑料排水立管通水能力的关键在于确定立管最大允许充水率α值.对不同通气条件下φ110 UPVC排水立管的通水能力及其终限流速进行实测,推导了塑料排水立管最大通水能力公式,得出塑料排水立管最大允许充水率α的推荐值为:伸顶通气管条件下0.15~0.18,专用通气立管条件下0.24~0.26.
The key to the solution of maximum discharge capacity of plastic drainage stack in building was to determine the maximum allowable fullness ratio, α of the stack. The discharge capacity of and terminal velocity in UPVC plastic stack(φ110 mm) were measured in different conditions of ventilation, and a formula of its maximum discharge capacity was derived. The recommended values of their maximum allowable fullness ratio was obtained as follows:α was taken as 0. 15 to 0. 18 for the stack with simple top-vent and 0. 24 to 0. 26 for the stack with special-purpose venting sysiem.
出处
《兰州理工大学学报》
CAS
北大核心
2007年第1期132-135,共4页
Journal of Lanzhou University of Technology
关键词
塑料排水立管
通水能力
充水率
plastic drainage stack
discharge capacity
fullness ratio