摘要
发现了Y/联结平衡变压器的相间电能传输现象.分析了相间电能传输的起因及其对变压器性能的影响.给出了减少相间电能传输绕组漏阻抗应满足的关系.这对Y/联结平衡变压器的设计。
A phenomenon of electric energy transmission was discoveried between the two phases of Y/ connected balance transformer. The phenomenon deteriorates the performance of the balance transformer. The cause has been found which produces the phenomenon and its effect on the transformer performance has been analyzed. A formula among the leakage impedances of windings, which can lighten the influence of the phenomenon, has been proposed.
出处
《西安交通大学学报》
EI
CAS
CSCD
北大核心
1996年第12期8-14,共7页
Journal of Xi'an Jiaotong University