期刊文献+

多层螺旋CT颞骨低剂量扫描的研究进展 被引量:7

The advances of application in low dose multi-slice spiral CT of the temporal bone
下载PDF
导出
摘要 低剂量CT扫描在保证诊断质量的前提下,对减少受检者的辐射损伤具有重要意义。本文介绍颞骨低剂量CT扫描的可行性、必要性和最新研究进展。 Low dose CT is very important value to insure diagnosis quality and reduce the patient's damages. This article summarizes the possibility, necessity and danger in low dose MSCT of the temporal bone.
出处 《医学影像学杂志》 2006年第12期1309-1311,共3页 Journal of Medical Imaging
关键词 颞骨 体层摄影术 X线计算机 剂量效应关系 辐射 Temporal bone Tomography, X- ray computed Dose response relationship, radiation
  • 相关文献

参考文献22

  • 1Rogers LF.Radiation exposure in CT:why is so high?[J].AJR,2001,177:277. 被引量:1
  • 2Nickoloff EL,Alderson PO.Radiation exposure to patients from CT:reality,public perception,and policy[J].AJR,2001,176:285-287. 被引量:1
  • 3ICRP publication 87:managing patient dose in computed tomography[J]. 被引量:1
  • 4Remy-Jardin M,Remy J.Spiral CT angiography of the pulmomary circulation[J].Radiology,1999,212:615-636. 被引量:1
  • 5Haaga JR.Radiation dose management:weighing risk versus benefit[J].AJR,2001,177:289-291. 被引量:1
  • 6尉可道.CT剂量的测量及其表达[J].中华放射医学与防护杂志,1997,17(5):347-351. 被引量:43
  • 7Hiles PA.A survey of patient dose and image quality for computed tomography scanners in Wales[J].Radiology,2001,21:345-354. 被引量:1
  • 8Jarry G,DeMarco JJ,Beifuss U,et al.A monte carlo-based method to estimate radiation dose from spiral CT from phantom testing to patient-specific models[J].Phys Med Biol,2003,48:2645-2663. 被引量:1
  • 9Wang L,Lovelock M,Chui CS.Experimental verification of a CT-based Monte Carlo dose-calculation method in heterogeneous phantoms[J].Phys Med,1999,26:2626-2634. 被引量:1
  • 10Groves AM,Owen KE,Courtney HM,et al.16-detector multi-slice CT:dosimetry estimation by TLD measurement compared with Monte Carlo simulation[J].BRJ,2004,77:662-665. 被引量:1

二级参考文献38

  • 1柳澄,秦维昌.多层螺旋CT(一)[J].医学影像学杂志,2000,10(3):194-195. 被引量:42
  • 2周康荣 等.螺旋CT[M].上海医科大学出版社,2001,8.. 被引量:2
  • 3Torizuka T, Hayakawa K, Satoh Y, et al. High-resolution CT of the temporal bone: a modified baseline. Radiology, 1992, 184: 109-111. 被引量:1
  • 4Anderhuber W , Weiglein A, Jakse R, et al. Muhiplanar angulated 2D reconstruction: a new CT technique for imaging the facial nerve canal. HNO, 1995, 43:76-79. 被引量:1
  • 5Rigatus H, Marchal G, Baert AL, et al. Spiral scanning and the influence of the reconstruction algorithm on image quality. Comput Assist Tomogr, 1990, 14:673-676. 被引量:1
  • 6Tomura N, Sashi R, Kobayashi M, et al. Normal variations of the temporal bone on high-resolution CT: their incidence and clinical significance. Clin Radiol ,1995, 50:144-148. 被引量:1
  • 7李松年.现代全身CT诊断学[M].北京:中国医药科技出版社,2001.1018. 被引量:166
  • 8Hein E, Rogalla P, Klingebiel R, et al. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose. Eur Radiol, 2002, 12:1693-1696. 被引量:1
  • 9Czechowski J, Janeczek J, Kelly G, et al. Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses. Eur Radiol, 2001, 11:711-713. 被引量:1
  • 10Kennedy DW, Zinreich SJ, Rosenbaum AE, et al. Functional endoscopic sinus surgery: theory and diagnostic evaluation. Arch Otolaryngol, 1985, 111:576-582. 被引量:1

共引文献223

同被引文献85

引证文献7

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部