期刊文献+

Study of Oligonucleotide Fixation on Bilayer Lipid Membranes by Patch-clamp Pipette Support

Study of Oligonucleotide Fixation on Bilayer Lipid Membranes by Patch-clamp Pipette Support
下载PDF
导出
摘要 One kind of novel BLMs was fabricated by patch-clamp pipette technology characterized in considerably sensitive to changes of electrochemical parameters.Detectiye currents and voltage presented linear relationship when BLMs was formed and it could be confirmed by Gramicidin method.Ion current was increased by dihexyl (C_ (12)) modified ssDNA fixed on the BLMs and also indicated linear relationship to ssDNA's concentration due to the interaction of (C_ 12)-ssDNA and BLMs.Further more,the regression equations were different from BLMs fixed with ssDNA probe and a blank control BLM in the same experimental conditions.The ssDNA probe was successfully fixed on patch-clamp pipette supported-BLMs.Based on our studies,a biosensor with reactive element of patch-clamp pipette-supported BLMs has been established. One kind of novel BLMs was fabricated by patch-clamp pipette technology characterized in considerably sensitive to changes of electrochemical parameters. Detectiye currents and voltage presented linear relationship when BLMs was formed and it could be confirmed by Gramicidin method. Ion current was increased by dihexyl(C12) modified ssDNA fixed on the BLMs and also indicated linear relationship to ssDNA's concentration due to the interaction of C12-55DNA and BLMs. Further more, the regression equations were different from BLMs fixed with ssDNA probe and a blank control BLM in the same experimental conditions. The ssDNA probe was successfully fixed on patch-clamp pipette supported-BLMs. Based on our studies, a biosensor with reactive element of patch-clamp pipette-supported BLMs has been established.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期324-326,共3页 Rare Metal Materials and Engineering
关键词 bilayer lipid membranes patch-clamp pipette OLIGONUCLEOTIDE bilayer lipid membranes patch-clamp pipette oligonucleotide
  • 相关文献

参考文献5

  • 1Novotny I, Rehacek V, Tvarozek V et al. Materials Science and Engineering C 5 [J], 1997:55. 被引量:1
  • 2Chen Jun. Experimental Technology of Patch-Clamp[M]. Beijing:Science Press, 2001. 被引量:1
  • 3Fajkus M, Hianik T. Talanta[J], 2002, 56:895. 被引量:1
  • 4Krull Ulrich J, Nikolelis D P, Jantzi Sarah C et al. Electroanalysis[J], 2000,12 : 921. 被引量:1
  • 5Siontorou Christina G Nikolelis Dimitrios P, Tarus Bogdan et al. Electroanalysis[J], 1998, 10:69. 被引量:1