摘要 介绍了兰州物理研究所正在进行的离子发动机空心阴极寿命试验。试验表明,该空心阴极在经过3 000 h放电工作后,状态稳定,未见衰退趋势。研究结果还表明,该空心阴极暴露大气后具有良好的抗中毒能力。 Ongoing life-test of hollow cathode has been introduced. The result indicated that the performance of hollow cathode has not show degradation trend after 3 000 hours life-test. The result has also showed the hollow cathode has good antipoisoning traits under air exposure condition.
机构地区 兰州物理研究所
出处 《真空与低温》 2006年第4期204-206,共3页 Vacuum and Cryogenics
关键词 电推进 空心阴极 寿命试验 electrical propulsion hollow cathode life-test
  • 相关文献

参考文献4

二级参考文献9

  • 1POLK J E.The Effect of Engine Wear on Performance in the NSTAR 8000 Hour Ion Engine Endurance Test[R].AIAA-97-3387. 被引量:1
  • 2TIMOTHY R,SARVER-VERHEY T R,Continuing Life Test of a Xenon Hollow Cathode for a Space Plasma Contactor[R].AIAA-94-3312. 被引量:1
  • 3TIMOTHY R,SARVER-VERHEY,Scenario for Hollow Cathode End-of-Life[R].NASA/CR-2000-209420. 被引量:1
  • 4TODD M JACK,STEPHEN W PATTERSON,DAVID G FEARN,The Effect of the Keeper Electrode of Hollow Cathode Characteristics[R].AIAA2000-3533 被引量:1
  • 5TIMOTHY R.SARVER-VERHEY.28,000 Hour Xenon Hollow Cathode Life Test Results[C].IEPC Paper No.97-168,Cleveland,Ohio,USA,1997. 被引量:1
  • 6JAMES S ZAKANY,LUIS R PINERO.Space Station Cathode Ignition Test Status at 32,000 Cycles[C].IEPC Paper No.97-167,Cleveland,Ohio,USA,1997. 被引量:1
  • 7G.C.SOULAS,Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor[R],AIAA94-3309. 被引量:1
  • 8TIMOTHY R,SARVER-VERHEY,MICHAEL J,et al.Microanalysis of Extended-Test Xenon Hollow Cathodes[R].AIAA-91-2123. 被引量:1
  • 9张世良,胡永年,吴国富,孙玉珠,赵翠萍.用于电子轰击式汞离子推力器空心阴极的实验研究[J]真空科学与技术,1982(01). 被引量:1

共引文献14

同被引文献68

引证文献14

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部