期刊文献+

Investigation of Peri-implant Status and Risk Variables for Implant Failure in Body of Maxilla after Oral Tumor Surgery

Investigation of Peri-implant Status and Risk Variables for Implant Failure in Body of Maxilla after Oral Tumor Surgery
下载PDF
导出
摘要 The aim of this study was to assess the peri-implant parameters and evaluate the clinical status with the survival of dental implants in body of maxilla after treatments of oral tumor. A follow-up examination included 27 patients who underwent the ablative tumor and (or) reconstructive surgery during a 5-year period. The follow-up protocol included clinical examination, radiological evaluation, and an interview using a standardized questionnaire. The reasons related to implant failure were studied by comparing the amount of failure with the value of marginal bone resorption, probing pocket depth, and plaque index using statistical t-test. The relationship between smoking and implant failure was analyzed statistically by chi-square test. The results showed among the 112 implants observed after implant loading, 29 have failed with the failure rate being 22.14 %. There was no significant correlation between the peri-implant status and the implant failure (P〉0.05), however, the association of smoking and implant failure was statistically tested (P〈0.05). It was suggested that the association of peri-implant status and implant failure in the maxilla after tumor surgery can't be statistically tested, however smoking was still a mainly significant factor. The aim of this study was to assess the peri-implant parameters and evaluate the clinical status with the survival of dental implants in body of maxilla after treatments of oral tumor. A follow-up examination included 27 patients who underwent the ablative tumor and (or) reconstructive surgery during a 5-year period. The follow-up protocol included clinical examination, radiological evaluation, and an interview using a standardized questionnaire. The reasons related to implant failure were studied by comparing the amount of failure with the value of marginal bone resorption, probing pocket depth, and plaque index using statistical t-test. The relationship between smoking and implant failure was analyzed statistically by chi-square test. The results showed among the 112 implants observed after implant loading, 29 have failed with the failure rate being 22.14 %. There was no significant correlation between the peri-implant status and the implant failure (P〉0.05), however, the association of smoking and implant failure was statistically tested (P〈0.05). It was suggested that the association of peri-implant status and implant failure in the maxilla after tumor surgery can't be statistically tested, however smoking was still a mainly significant factor.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第6期756-758,共3页 华中科技大学学报(医学英德文版)
关键词 oral tumor peri-implant MAXILLA oral tumor peri-implant maxilla
  • 相关文献

参考文献10

  • 1Buser D,Merickse-Stern R,Bernard J P et al.Long-term evaluation of nonsubmerged ITI implants Part 1: 8-year life table analysis of a prospective multicenter study with2359 implants[].Clinical Oral Implants Research.1997 被引量:1
  • 2Branemark P I,,Svensson B,van Steenberghe D.Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism[].Clinical Oral Implants Research.1995 被引量:1
  • 3Cao T G,,Weischer T,Zhou B.Long-term observation of maxillary implants after oral cancer treatment[].Acta Med Univ Sci Technol Huazhong (Chinese).2003 被引量:1
  • 4Bain C A,Moy P K.The association between the failure of dental implants and cigarette smoking[].Int J Oral Max- illofac Implants.1993 被引量:1
  • 5De Bruyn H,Collaert B.The effect of smoking on early implant failure[].Clinical Oral Implants Research.1994 被引量:1
  • 6Quigley G A,Hein J W.Comparative cleaning efficiency of manual and power brushing[].The Journal of The American Dental Association.1962 被引量:1
  • 7Flemming T F,H?ltje W J.Periimplant?re Mukosa und Knochen bei Titanimplantaten[].Z Zahn?rztl Implantol.1988 被引量:1
  • 8Adell R,Lekholm U,Rockler B.Marginal tissue reac- tions at osseointegrated titanium fixtures (I) A 3-year longitudinal prospective study[].International Journal of Oral and Maxillofacial Surgery.1986 被引量:1
  • 9Million R,Cassisi N.Management of Head and Neck Cancer: a Multidisciplinary Approach[]..1994 被引量:1
  • 10Kovács A.The fate of osseointegrated implants in pa- tients following oral cancer surgery and mandibular reconstruction[].Head and Neck.2000 被引量:1