期刊文献+

心肌磁共振显像、核素心肌灌注显像、超声心动图与X线左心室造影测定左心室功能的对比研究 被引量:5

A Comparative Study of Cardiac Magnetic Resonance Imaging,Electrocardiogram-Gated Single-Photon Emission Computed Tomography and Echocardiography With Left Ventriculography
下载PDF
导出
摘要 目的:评价心肌磁共振显像(MRI)、核素心肌灌注显像和超声心动图对比X线左心室造影(LVG)检测左心室功能的应用价值。方法:46例患者同期分别行左心室造影、心肌磁共振显像、核素心肌灌注显像(30例)及超声心动图(38例)检查,测定左心室功能。将左心室造影作为标准,与其它3种影像学方法比较,行相关性及一致性分析。结果:心肌磁共振显像与左心室造影所测左心室舒张末期容积、收缩末期容积和射血分数的相关系数分别为0.94、0.98、0.96(P均<0.001),核素心肌灌注显像与左心室造影的相关系数分别为0.82、0.90、0.93(P均<0.001),超声心动图与左心室造影的相关系数分别为0.66、0.74、0.69(P均<0.001)。心肌磁共振显像与左心室造影所测舒张末期容积、收缩末期容积和射血分数一致性范围分别为(-21.4±31.8)ml,(-7.7±25.0)ml,(-2.2±8.8)%。核素心肌灌注显像与左心室造影的一致性范围分别为(-36.8±53.1)ml,(-15.2±32.2)ml,(-2.6±11.0)%。超声心动图与左心室造影的一致性范围分别为(-80.9±95.8)ml,(-47.5±96.0)ml,(3.6±21.1)%。结论:心肌磁共振显像检测心功能准确、可靠,与左心室造影相关性明显,一致性好。核素心肌灌注显像与左心室造影亦具有良好的相关性,但一致性偏差。超声心动图左心功能测值较左心室造影有明显偏倚,一致性差。 Objective :To compare of accuracy of cardiac magnetic resonance imaging ( MRI), electrocardiogram-gated single-photon emission computed tomography (SPECT) and echocardiography with X-ray left ventriculography (LVG) in assessment of left ventficular function. Methods:LVG and MRI were performed in 46 patients, SPECT was performed in 30 patients, and echocardiography was performed in 38 patients, left ventricular function were estimated with MRI, SPECT and echocardiography. The results were compared with the gold standard of LVG. Statistical evaluation of correlation and agreement was done. Results: The correlation between MRI and LVG for end-diastolic volume, end-systolic volume and ejection fraction were 0. 94,0.98 and 0. 96, respectively( P 〈 0. 001 ). The correlation coefficiency between SPECT and LVG were 0. 82,0. 90 and 0.93 ( P 〈 0. 001 ). The correlation coefficiency between echocardiography and LVG were 0. 66,0. 74 and 0. 69 ( P 〈 0. 001 ). The limits of agreement of end-diastolic volume, end-systolic volume and ejection fraction between MRI and LVG were( -21.4 ± 31.8 ) ml, ( - 7.7 ± 25. 0) ml and ( - 2.2 ± 8.8) %, respectively. The limits of agreement between SPECT and LVG were( - 36. 8 ±53.1 ) ml, ( - 15.2 ± 32. 2 ) ml and ( - 2. 6 ± 11.0) %, respectively. The limits of agreement between echocardiography and LVG were ( - 80. 9 ± 95.8 ) ml, ( - 47. 5 ± 96. 0 ) ml and ( 3.6 ± 21.1 ) %, respectively. Conclusion: MRI is reliable and accurat in measuring cardiac function,and shows a high correlation and agrrement between MRI and LVG. It also shows a good correlation but mild agrrement between SPECT and LVG. However, the value in measuring left ventricular function is deviated by echocardiography.
出处 《中国循环杂志》 CSCD 北大核心 2006年第6期449-452,共4页 Chinese Circulation Journal
关键词 左心室造影 心肌磁共振显像 核素心肌灌注显像 超声心动图 左心室功能 Left ventriculography Cardiac magnetic resonance imaging Electrocardiogram-gated single-photon emission computed tomography Echocardiography Left ventricular function
  • 相关文献

参考文献12

  • 1Pfeffer MA,Braunwald E,Moye LA,et al.Effect of captopril on mortality and morbidity in patients with left ventricular dysfunction after myocardial infarction:results of the survival and ventricular enlargement trial-the SAVE Investigatores.N Engl J Med,1992,327:669-677. 被引量:1
  • 2The GUSTO Angiographic Investigators.The effects of tissue plasminogen activator,streptokinase,or both on coronary-artery patency,ventricular function,and survival after acute myocardial infarction.N Engl J Med,1993,329:1615-1622. 被引量:1
  • 3Cranney GB,Lotan CS,Dean L,et al.Left ventricular volume measurement using cardiac axis nuclear magnetic resonance imaging.Validation by calibrated ventricular angiography.Circulation,1990,82(1):154-163. 被引量:1
  • 4Longmore DB,Klipstein RH,Underwood SR,et al.Dimensional accuracy of magnetic resonance in studies of the heart.Lancet,1985,1(8442):1360-1362. 被引量:1
  • 5Sakuma H,Fujita N,Foo TK,et al.Evaluation of left ventricular volume and mass with breathhold cine MR imaging.Radiology,1993,188 (2):377-380. 被引量:1
  • 6Hoffmann R,yon Bardeleben S,ten Cate F,et al.Assessment of systolic left ventricular function:a multi-centre comparison of cineventriculography,cardiac magnetic resonance imaging,unenhanced and contrast-enhanced echocardiography.Eur Heart J,2005,26(6):607-616. 被引量:1
  • 7Heusch A,Koch JA,Krogmann ON,et al.Volumetric analysis of the right and left ventricle in a porcine heart model:comparison of three-dimensional echocardiography,magnetic resonance imaging and angiocardiography.Eur J Ultrasound,1999,9:245-255. 被引量:1
  • 8Grebe O,Kester HA,Merkle N,et al.Assessment of left ventricular function with steady-state-free-precession magnetic resonance imaging.Reference values and a comparison to left ventriculography.Z Kardiol,2004,93 (9):686-695. 被引量:1
  • 9Kondo C,Fukushima K,Kusakabe K.Measurement of left ventricular volumes and ejection fraction by quantitative gated SPECT,contrast ventriculography and magnetic resonance imaging:a meta-analysis.Eur J Nucl Med Mol Imaging,2003,30(6):851-858. 被引量:1
  • 10Ioannidis JP,Trikalinos TA,Danias PG.Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction:a meta-analysis.J Am Coll Cardiol,2002,39(12):2059-2068. 被引量:1

同被引文献66

引证文献5

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部