期刊文献+

IPS Empress-2全瓷修复体的临床研究 被引量:5

Retrospective clinical study on IPS Empress-2 all-ceramic restorations
下载PDF
导出
摘要 目的评价IPS Empress-2全瓷修复体的临床效果。方法为51例患者制作了63件IPS Empress-2全瓷冠桥,戴用期为12.36个月,平均24个月,采用美国加利弗尼亚牙科协会评价标准,对修复体边缘完整性、解剖外形、颜色、表面等进行临床评价,并对修复体戴用后的菌斑指数和牙龈指数进行统计学分析。结果IPS Empress-2全瓷冠桥的满意率为96.8%,边缘位于龈上和齐龈的冠桥修复体的牙龈健康状况与对照组无统计学差异,边缘位于龈下的修复体牙龈指数记分为2的比率显著高于对照组。结论IPS Empress-2全瓷修复体的近期修复效果良好。 Objective To investigate the clinical performance of IPS Empress2 all-ceramic restorations. Methods 51 patients were restored with 63 IPS-Empress 2 full-ceramic crowns and three-unit bridges. The range of clinical service was 12 - 36 months with the average of 44 months. Marginal integrity, anatomic form, color and surface of the restorations were evaluated according to California Dental Association criteria. Statistical analyses of plaque index(PI) and gingival index(GI) were carried out by use of rank sum test. Results The satisfactory rate of IPS-Empress 2 full-ceramic restorations was 96.8 %. There was no statistic difference of gingival health condition between control group and groups with restoration margin lying above/at the level of gingiva margin, and the rate of GI score 2 in subgingival margin group was higher than that of control group. Conclusion The short-term clinical behavior of IPS Empress2 all-ceramic restorations is encouraging.
出处 《口腔医学》 CAS 2006年第6期445-447,共3页 Stomatology
关键词 S Empress-2 全瓷冠桥 IPS Empress2 all-ceramic crowns and bridges
  • 相关文献

参考文献8

  • 1Gemlamaz D,Ergin S.Clinical evaluation of all-ceramic crowns[J].J Prosthet Dent,2002,87(2):189-196. 被引量:1
  • 2Loee H,Silness J.Periodontal disease in pregnancy (Ⅰ).Prevalence and severity[ J ].Acta Odontol Scand,1963,21(11):533-551. 被引量:1
  • 3Silness J,Loee H.Periodontal disease in pregnancy (Ⅱ).Correlation between oral hygiene and periodontal condition[ J ].Acta Odontol Scand,1964,22(2):121-135. 被引量:1
  • 4Gungor MA,Kucuk M,Dundar M,et a l.Efeet of temperature and stress distribution on all-ceramic restorations by using a three dimensional finite element analysis[J].J Oral Rehabil,2004,31 (2):172 -178. 被引量:1
  • 5Yeo IS,Yang JH,Lee JB.In vitro marginal fit of three all ceramic crown systems[J].J Prosthct Dent,2003,90(5):459-464. 被引量:1
  • 6Sjogren G,Lantto R,Granberg A,et al.A clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice:a retrospective study[J].Inl J Prosthodont,1999,12(2):122-128. 被引量:1
  • 7Marquardt P,Strub JR.Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures:results of a 5-year prospective clinical study[J].Quintessence Int,2006,37(4):253-259. 被引量:1
  • 8Vichi A,Ferrari M,Davidson CL.Iffluence of ceramic and cement thickness on the masking of various types of opaque posts[ J ].J Prosthet Dent,2000,83(4):412-417. 被引量:1

同被引文献41

引证文献5

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部