期刊文献+

模块式高温气冷堆超临界蒸汽发生器设计 被引量:12

Supercritical Steam Generator Design of Modular High-Temperature Gas-Cooled Reactor
下载PDF
导出
摘要 本工作涉及用于模块式高温气冷堆的超临界蒸汽发生器的设计参数。研究给出了传热管束的螺旋管结构设计方案和结构尺寸,并分析了其在超临界压力下的传热特性。热工水力分析计算结果证明,所设计的超临界蒸汽发生器能够满足传热和水力要求,且在设计工况下不会发生传热恶化。 The research concerns in the technical parameters of supercritical direct current steam generator used in modular high-temperature gas-cooled reactor (MHTR). The helical tube structure design concept and structure size of transfer heat tube bundle were provided, and the heat transfer characteristics of tube bundle at supercritical pressure were analysed. Based on the thermal hydraulic analysis and calculation, the design is proved to meet the thermal and hydraulic requirements and not occur the heat transfer deterioration at the design condition.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2006年第6期707-713,共7页 Atomic Energy Science and Technology
关键词 高温气冷堆 超临界压力 蒸汽发生器 螺旋管 传热恶化 modular high-temperature gas cooled reactor supercritical pressure steam generator helical tube heat transfer deterioration
  • 相关文献

参考文献11

二级参考文献79

  • 1田永生,陈听宽,徐进良,罗毓珊.超临界压力下水在倾斜管内传热特性的研究[J].化工学报,1993,44(1):34-40. 被引量:6
  • 2卢锦蔷.国内外600MW级火电大机组技术特点、运行分析及选型[M].湖北电力工业局,1996.64. 被引量:1
  • 3.超临界汽轮机文集[M].哈尔滨汽轮机厂有限责任公司出版,.. 被引量:1
  • 4.ALSTOM公司超临界及超超临界机组资料[Z].ALSTOM公司,2002.. 被引量:1
  • 5.SD264-88.火力发电厂汽轮机、锅炉、汽轮发电机参数系列标准[S].,.. 被引量:1
  • 6A.Kawamura.七尾大田火力l所2Cの特徵と\结果[J].火力原子力发电,1999,(9). 被引量:1
  • 7N.Funayama H.Asano.原町火力l所2Cの特徵と\I[J].火力原子力发电,1999,(9). 被引量:1
  • 8T.Mizobuchi Y.Wajiki S.Fujikawa.橘湾l所の概要と建O状况[J].火力原子力发电,1999,(9). 被引量:1
  • 9岩永清.川越火力l所12Cの建O\[J].火力原子力发电,1990,(4). 被引量:1
  • 10.东芝公司超临界及超超临界机组资料[Z].东芝公司,2002.. 被引量:1

共引文献110

同被引文献76

引证文献12

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部