期刊文献+

论城市与建筑环境的互动关系 被引量:2

Interactive Relationships between Urban and Building Environments
原文传递
导出
摘要 本文论述了城市环境与建筑环境所对应的不同空间尺度以及研究内容上的差别,分析了城市与建筑环境的复杂互动关系,并通过相关研究现状的介绍,指出探讨两者之间的相互作用关系,对于分析它们的形成机理,进而改善目前城市和建筑环境中暴露的问题,建设可持续发展的城市与建筑环境具有重要意义。而由于该研究涉及到现有学科体系的交叉领域,尚有许多课题有待深入研究。本文在最后从建筑环境与设备学科的角度,对今后的工作进行了展望。 In this paper, urban and building environments were firstly identified from the viewpoints of space scale and research issues, and then the complicated interactive relationships between urban and building environments were analyzed. Based on the introduction of research status, the mechanism and interactive relationships were indicated, which was very important for the development of sustainable urban and building environments. However, because different related disciplines should be considered, further investigation was needed. Therefore, future research work for this issue was proposed at the end of the paper.
作者 刘京 朱岳梅
出处 《建筑科学》 北大核心 2006年第B06期10-12,25,共4页 Building Science
基金 国家自然科学基金资助项目(40505025)
关键词 城市环境 建筑环境 空调人工排热 热舒适 urban environment building environment anthropogenie heat by HVAC thermal comfort
  • 相关文献

参考文献11

  • 1村上周三.CFDによる建筑·都市的环境设计工学[M].日本:东京大学出版会,2()oo. 被引量:1
  • 2Jozwiak R, Kacprzyk J,Zuranski JA, Influence of wind direction on natural ventilation of apartment buildings [ J ], Joural of Wind Engineering and Industrial Aerodynamics, 1996(60) : 167 - 176. 被引量:1
  • 3Rosenfeld A H, Akbari H, Bretz S. Mitigation of urban heat islands:materials, utility programs, updates [ J ]. Energy and Buildings, 1995(22) :255-265. 被引量:1
  • 4Inose T,Shimodozono K, Hanaki K. Impact of anthropogemic heat on urban climate in Tokyo [ J ]. Atmosphere Environment, 1999 ( 33 ) :3897 - 3909. 被引量:1
  • 5王长庆,龙惟定,丁文婷.各种冷源的一次能耗及对环境影响的比较[J].节能技术,2000,18(4):8-10. 被引量:17
  • 6田喆,黄勇波,朱能,黎贞发.城市热岛作用下办公建筑冷负荷的影响因素分析[J].流体机械,2005,33(5):54-57. 被引量:7
  • 7村上周三,松繩堅.建筑物的综合环境性能评价手法CASBEEに関する研究(その18-20)[C].日本建筑学会大会讲演梗概集,2004(D-1):1101~1106 被引量:1
  • 8村上周三,金相進.ヒ-トアィラド现象の解析とその对策技术の综合的评价のためのSoftware Platformの開発(その1)概念设计とPrototype Systemの構成[C].日本建筑学会大会学術講演梗概集,2000. 被引量:1
  • 9钱炜,唐鸣放,郑怀礼.城市户外热环境的舒适性研究[J].重庆环境科学,2002,24(2):88-89. 被引量:13
  • 10Nikolopoulou M, Baker N, Stcemers K. Thermal comfort in outdoorurban spaces : understanding the human parameter [ J ]. Solar Energy,2001,70(3) :227 - 235. 被引量:1

二级参考文献16

  • 1陆鼎煌.北京区绿化与民居夏季舒适度[J].北京林业,1984,1:28-36. 被引量:2
  • 2Ojima T. Changing Tokyo metropolitan area and its heat island model[J]. Energy & Buildings, 1991. 191-203. 被引量:1
  • 3Santamouris M, Papanikolaou N. On the impact of urban climate on the energy consumption of buildings [ J ]. Solar Energy, 2001, 70 (3):201-216. 被引量:1
  • 4Hassid S, Santamouris M. The effect of the Athens heat island on air conditioning load [ J]. Energy & Buildings,2000, 32(2): 131-141. 被引量:1
  • 5Joyce Carlo, Roberto Lamberts. Urban climate and its influence on energy consumption: A case study in two Brazilian cities[ A]. Seventh Building Energy Simulation Conference Proceedings[C] .Rio de Janeiro, Brazil, IBPSA, 2001,August. 167-174. 被引量:1
  • 6Crawley D B, et al. EnergyPlus: Energy Simulation Program[J]. ASHRAE Journal,2000,42(4) :49-56. 被引量:1
  • 71999 ASHRAE Handbook. HVAC application[M]. American Society of Heating, Refrigeration and Air Conditioning Engineerings,Inc. 1999. 被引量:1
  • 8K.H. Yang, S. C. Wu, Y. S. Chiang, W. C. Chen,W. F. Liao. The auditing and analysis of commericial building energy conservation design in Taiwan[R].Proceedings of air conditioning in high rise buildings'97.September, 1997.Shanghai,China. 被引量:1
  • 9严德隆,张维君.空调制冷及热电冷联产系统的能耗分析[J].暖通空调,1998,28(6):18-22. 被引量:21
  • 10闫斌,郭春信,程宝义,缪小平.舒适性空调室内设计参数的优化[J].暖通空调,1999,29(1):44-45. 被引量:46

共引文献32

同被引文献40

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部