摘要
论述了地区电网常见的一些故障及故障的处理方法,结合江苏无锡地区电网运行特点及各种故障现象,探讨了值班调度员如何去正确、快速判断及处理故障,并针对一些实际典型事故进行了分析,总结了无锡地区的事故处理经验,以保障电网安全、稳定运行。
The paper elaborated some typical faults and their processing methods in local electrical network. It discussed how the on-duty dispatcher judge and process faults correctly and fastly,integrating with the Wuxi electrical network operation characteristics and all kinds of faults. The paper analyzed some actual typical accidents and summarized fault process experience in order to safeguard secure and stable operation of the grid.
出处
《江苏电机工程》
2006年第6期11-13,共3页
Jiangsu Electrical Engineering
关键词
地区电网
故障
跳闸
local electrical network
fault
trip