摘要
对氯化锂-水吸附式空调系统在再循环运行方式下的性能进行了模拟。分析了再生温度、热交换器效率及蒸发冷却器效率对性能的影响。与开式通风型空调制冷系统的制冷性能相比,再循环型空调制冷系统的制冷能力较大。
The performance of lithium chloride water vapor desiccant cooling system operating in the recirculation mode was modelled numerically.The effects of regeneration temperatrue,heat exchanger effectiveness and evaporative cooler effectiveness on system performance were investigated.Compared with the system operating in the ventilation mode,the system operating in the recirculation mode has bigger cooling capacity and smaller the value of coefficient of performance.
出处
《化学工程》
CAS
CSCD
北大核心
1996年第6期12-17,共6页
Chemical Engineering(China)
关键词
氯化锂
再循环型
空气调节
制冷系统
性能
Lithium chloride,recirculation mode,air conditioning,rotary dehumidifier,rotary heat exchanger,coefficient of performance