摘要 在“强光一号”装置驱动电流峰值1.4—2.1MA、上升时间80—100ns条件下,研究了不同丝阵直径、丝数及丝直径的钨丝阵负载Z箍缩等离子体的辐射特性.用自行研制的测试系统对等离子体辐射参数进行了诊断.实验获得的最大X射线总能量为34kJ,最大峰值功率为1.28TW.得到了一些关于钨丝阵Z箍缩等离子体辐射特性的规律性认识. Experimental study on plasma radiation characteristics of W wire array Z pinch with different initial parameters performed on Qiangguang- Ⅰ pulsed power generator of 1.4-2.1MA current with 80-100ns rise time is reported. The generator configuration and the diagnostic system for the experiments are briefly described. The total X-ray energy and peak power have been measured, and the maximum of X-ray energy and peak power are 34kJ and 1.28TW, respectively. In additional, the main results and conclusions are discussed also.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2006年第11期5917-5922,共6页 Acta Physica Sinica
基金 国家自然科学基金重点项目(批准号:10035020)资助的课题.~~
关键词 钨丝阵 Z箍缩 等离子体辐射 W wire array, Z-pinch, plasma radiation
  • 相关文献

参考文献2

二级参考文献16

  • 1常增虎,山冰,刘秀琴,杨鸿儒,朱文华,刘进元,侯继东,龚美霞.微通道板选通X射线皮秒分幅相机[J].光子学报,1995,24(6):501-508. 被引量:15
  • 2国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.29-44. 被引量:158
  • 3Sanford T W L, Mock R C, Spielman R B, et al. Increased X-ray power generated from low-mass large-number aluminum-wire-array Z-pinch implosions[J]. Physics of Plasma, 1998, 5(10):3755-3763. 被引量:1
  • 4Aliaga-R R, Lebedev S V, Chittenden J P, et al. Optical measurements of plasma dynamics in carbon fiber Z-pinches[J]. IEEE Trans Plasma Sci, 1998, 26(4):1101-1107. 被引量:1
  • 5郑志坚. "神光II"激光装置上的诊断系统[A]. 核聚变与等离子体应用学术讨论会会议文集[C]. 成都: 1998.(Zheng Z J. The diagnostics for laser device of Sheng-Guang-II. In:Proc Conf applications of nuclear fusion and plasmas. Chengdu, China, 1998) 被引量:1
  • 6蒯斌, 邱爱慈, 曾正中, 等. XH-1装置喷Z-pinch等离子体负载[A]. 第九届全国等离子体科学技术会议[C]. 大连: 1999. 384-387.(Kuai B, Qiu A C, Zeng Z Z, et al. Gas puff Z-pinch load of XH-1 generator. in Proc 9th conf plasma science and technology, Dalian, China, 1999. 384-387) 被引量:1
  • 7丁臻捷, 蒯斌, 邱爱慈, 等.利用真空X射线二极管测量Z-pinch热辐射谱的方法[A]. 第九届全国等离子体科学技术会议[C]. 大连:1999. 391-394.(Ding Z J, Kuai B, Qiu A C, et al. Method using vacuum X-ray diode to measure radiation spectrum of Z-pinch. In:Proc 9th conf plasma science and technology. Dalian, China, 1999. 391-394) 被引量:1
  • 8Henke B L, Knauer J P, Premaratne K. The characterization of X-ray photocathodes in the 0.1~10keV photon energy region[J]. J Appl Phys, 1981, 52(3):1509-1520. 被引量:1
  • 9Hei D W, Wang K L, Liu G L. X-ray spectrometer for Z-pinch plasma radiation source[A]. In:Proc 9th conf plasma science and technology[C]. Dalian, China, 1999.380-383. 被引量:1
  • 10Saloman E B, Hubbell J H, Scofield J H. X-ray attenuation cross sections for energies 100eV to 100keV and elements Z=1 to Z=92[J]. Atomic Data and Nuclear Data Tables, 1988, 38(1):1-197. 被引量:1