研究了参考有功功率和参考无功功率的确定原则和优化计算,进而探讨了发电机的功率解耦控制原理,给出了完整的交流励磁变速恒频风力发电机最优功率控制策略。仿真研究表明,基于参考功率优化计算和矢量控制技术的最优功率控制,可以有效地追踪最大风能,降低发电机损耗,提高风电机组的运行效率和性能。
Active & reactive power output of AC-exited VSCF wind power generator can be controlled independently by applying vector transformation control technique. The maximal wind power can be captured based on generator power control. Appropriate selection for reference power of generator is critical to the generator power control. Not only the method of active & reactive reference power was discussed in this paper. The optimal power control scheme was fully given out at last. Simulation investigation shows that not only the maximal wind power is captured, but also copper loss decreases, run efficiency and performance are greatly improved through the optimal power control, which is based on optional reference power calculation and vector control technique.
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
2006年第10期1014-1020,共7页
Acta Energiae Solaris Sinica
关键词
交流励磁
变速恒频
最大风能捕获
矢量变换控制
功率控制
AC-exited
VSCF
the maximal wind power capture
vector transformation control
power control