摘要
介绍了该别墅地埋管地源热泵空调系统中地埋管换热器的计算方法。给出了一组冬季和夏季的运行数据。数据表明,该空调系统的供热量、制冷量、性能系数等基本能达到设计指标,冬季的换热器吸热量略小于设计值,应考虑适当的余量。
Presents the calculating method of ground heat exchanger in the ground-source heat pump system. Represents the operating data in summer and winter of a year. As a result, the heating capacity, cooling capacity and COP of the system can meet the design conditions, and the heat charge capacity of the heat exchanger is slightly smaller than the design condition, and an appropriate allowance should be considered.
出处
《暖通空调》
北大核心
2006年第9期65-67,104,共4页
Heating Ventilating & Air Conditioning
基金
河北省教育厅资助项目(编号:2003209)
关键词
地源热泵系统
别墅
测试
分析
ground-source heat pump system, villa, test, analysis