期刊文献+

非接触光镊法研究混合液体黏滞系数的组分关系 被引量:2

Studying the relationship between the viscosity and the concentration of solutions by using technology of optical tweezers
原文传递
导出
摘要 利用光镊技术对一组质量百分比含量不同的乙醇水溶液在30oC下的黏度进行了测量,其结果与理论估算的一致,二者之间的偏差为10%左右;此外,得到的黏度随乙醇含量的变化规律与20oC、40oC时的相同。验证了基于光镊非接触操控方法在易挥发液体及其混合溶液黏度测量的实用价值。 The viscosity of a group of the ethanol - water solutions of different ethanol concentration at 30℃ were measured, and the result consisted with theoretical value with a relative error about 10%. More is that the relationship between the viscosity and the concentration of solutions got here is similar to those of 20℃ and 40℃. All these demonstrated that is a valuable method of measuring viscosity of the volatile liquid or its solutions due to the non - contact feature of the optical manipulation.
出处 《应用激光》 CSCD 北大核心 2006年第4期257-260,共4页 Applied Laser
基金 国家自然基金(10474094) 中科院知识创新工程(KJCX2)资助
关键词 光镊 非接触法 布朗运动 黏滞系数 Optical tweezers Non -contact way Brownian motion Viscosity
  • 相关文献

参考文献17

二级参考文献23

共引文献45

同被引文献23

  • 1李银妹,魏勋斌,朱天,鲁润龙.光钳捕获、操纵、分离和模拟提取酵母细胞[J].激光生物学,1993,2(1):193-195. 被引量:5
  • 2BERTHUY O I,BLUM L J,MARQUETTE C A.Cells on chip for multiplex screening[J].Biosensors and Bioelectronics,2016,76:29-37. 被引量:1
  • 3HE R,ZHAO L,LIU Y,et al.Biocompatible TiO2nanoparticle-basedcell immunoassay for circulating tumor cells capture and identification from cancer patients[J].Biomed Microdevices,2013,15(4):617-626. 被引量:1
  • 4SHENG W,OGUNUWOBI O O,CHEN T,et al.Capture,release and culture of circulating tumor cells from pancreatic cancer patientsusing an enhanced mixing chip[J].Lab Chip,2014,14(1):89-98. 被引量:1
  • 5TAN S J,YOBAS L,LEE G Y,et al.Microdevice for the isolation andenumeration of cancer cells from blood[J].Biomed Microdevices,2009,11(4):883-892. 被引量:1
  • 6OKANO H,SUYAMA K,ARIYASU S,et al.Screening of circulating tumor cells in tumor-bearing mouse blood by a deterministic lateral displacement micro fluidic device[C]//Proceedings of the 17th International Conference on Miniaturized Systems for Chemistry and Life Sciences.Freiburg,Germany,2013:1021-1023. 被引量:1
  • 7EARHART C M,HUGHES C E,GASTER R S,et al.Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips[J].Lab Chip,2014,14(1):78-88. 被引量:1
  • 8ALAZZAM A,STIHARU I,BHAT R,et al.Interdigitated comb-like electrodes for continuous separation of malignant cells from blood using dielectrophoresis[J].Electrophoresis,2011,32(11):1327-1336. 被引量:1
  • 9ASHKIN A,DZIEDZIC J M,YAMANE T.Optical trapping and manipulation of single cell using infrared laser beams[J].Nature,1987,330:769-771. 被引量:1
  • 10ASHKIN A,DZIEDZIC J M.Optical trapping and manipulation of viruses and bacteria[J].Science,1987,235(4795):1517-1520. 被引量:1

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部