期刊文献+

660MW机组低负荷3台磨煤机运行可行性探讨 被引量:2

Feasibility Study of Putting 3 Coal Pulverizers into Operation during Low Load of 660MW Unit
下载PDF
导出
摘要 华能德州电厂为了实现机组的经济运行,提出了低负荷时3台磨煤机运行的方案。文章介绍了华能德州电厂制粉系统的配置和性能参数,对3台磨煤机运行的可行性作了试验分析,并从锅炉稳燃、低负荷运行存在的问题和经济性等方面进行了探讨。最后给出了3台磨煤机低负荷稳定运行的建议。 For realizing the economic operation of generating unit Hnaneng Dezhou power plant put forward the scheme of putting 3 coal pulverizers into operation during low load. The paper briefed the allocation and performance parameters of coal pntverizing system ha Huaneng Dezhou power plant,conducted the testings and analysis of feasibility of putting 3 coal pulverizers into operation,and carried out the approaches from the existing problems ha boiler steady combustion and low load operation as well as the economics ere.aspects. Fhaally the paper raised the proposals on the low load steady operation of 3 coal pulverizers.
机构地区 华能德州电厂
出处 《电力设备》 2006年第10期53-57,共5页 Electrical Equipment
关键词 节能 直吹式制粉系统 稳燃 发电厂 energy saving direct- firhag pulverizing system steady- state combustion
  • 相关文献

参考文献2

  • 1电力行业职业技能鉴定指导中心编..锅炉运行值班员[M].北京:中国电力出版社,2001:413.
  • 2中国动力工程学会主编..火力发电设备技术手册 第4卷 火电站系统与辅机 第5章 燃料输送系统[M].北京:机械工业出版社,1998:26.

同被引文献12

引证文献2

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部