介绍了干式变压器在高层建筑现场装配的解决方案,包括根据现场运载条件及空间限制对变压器进行分拆并包装,现场装配应尊宪的标准及操作流程,现场装配时所需要的操作空间和应准备的必要的操作工具,现场装配完成后为考核变压器的装配质量必须进行的试验等。
In this paper, the solution of assembling dry transformers, which are in tall building, is introduced. There include, taking apart the transformer according to the load and space of the carrying elevator, packing, transportation, standard, assembling flow, operating space and the tools, and the tests after assembling.