摘要
饮用水源水质安全直接关系到广大人民群众的健康。介绍了张家港饮用水源地水质自动遥测预警系统构成和功能,并对水温、pH、电导率、溶解氧四个可比性较强的项目进行了比测分析。经过了1年的实际运行,表明自动遥测系统性能稳定,接受数据完整可靠,预警系统达到了预期的良好效果。
Drinking water source safety concerns the broad masses of the people's health. This article describes the structure and functions of the automatic telemetry warning system for drinking water source quality of Zhangjiagang, and makes comparative measurement and analysis of 4 parameters with higher comparability, such as water temperature, PH value, conductivity, dissolved oxygen. Normal operation over one year shows that the automatic telemetry system has features of higher stability, also higher data integrality and reliability, and that the warning system has achieved the good desired results.
出处
《水利水文自动化》
2006年第3期13-16,共4页
Automation in Water Resources and Hydrology
关键词
饮用水源地
水质
自动
遥测
预警系统
drinking water source
water quality
automation
telemetry
waming system