期刊文献+

锗渣中锗的测定——碘酸钾容量法 被引量:7

The Determination of Gemenium in Gemenium Slag——Potassium Iodate titrimetry
下载PDF
导出
摘要 文章采用氢氧化钠碱熔试样,经硫酸中和后,在1+1盐酸介质中蒸馏分离锗,使大部分干扰元素经蒸馏分离,并在1+1盐酸介质中用碘酸钾容量法滴定锗。该法滴定终点明显,准确率高。标准回收率为95.52%~105.78%,变异系数为3.18%~4.42%。适用于锗渣中高含量的锗的测定分析。 The sample was dissolved by Sodium Hydroxide, and then heutralized by Sulfuric Acid. Finally it was distilled to separate Gemenium from the co-exist elements in Hydrochloric Acid (1 + 1) Medium. In Hydrochloric Acid (1 + 1) Medium, Gemenium was titrated by potassiumiodate standard solution. This method has a distinct titration end point and high accuracy. The standard recovery is in the range of 95.52% - 105.78%. The relative standard deviation RSD) is less than 4.42%. It can be used to determine the high Gemenium content in Gemenium slag.
作者 左鸿毅
机构地区 韶关冶炼厂
出处 《湖南有色金属》 CAS 2006年第5期56-58,共3页 Hunan Nonferrous Metals
关键词 锗渣 碱熔 碘酸钾 Gemenium slag Gemenium potassium iodate Sodium Hydroxide