全膜法水处理工艺在火力发电厂循环水排污水回用方面的应用 被引量:17

Application of Complete Membrane Method Water Treatment Technology in the Recovery Use of Circulating Water Blowdown in Thermal Power Plant
下载PDF
导出
摘要 本文详细介绍了全膜法水处理设备在循环水排污水回用方面的应用情况,总结了系统运行方面的经验,提出了系统设计与运行方面值得注意的问题。 The paper details the application status of complete membrane method water treatment technology in the recovery use of circulating water blow down in thermal power plant,sums up.The experience with the system operation,analyzes the abnormal cases in the operation, such as the blocking problem of safety filter and reverse osmosis membrane, and the operation faults of system arising from allocation cause etc.,and gives the solving scheme.In addition,the paper also puts forward the problems worth attention in the design and operation of system.
作者 赵荧
机构地区 北京高井热电厂
出处 《电力设备》 2006年第8期78-80,共3页 Electrical Equipment
关键词 膜技术 超滤 反渗透 电除盐 membrane technology ultra filtration reverse osmosis clectrodemineralization
  • 相关文献

参考文献3

  • 1[1]时均,袁权等.膜技术手册.北京:化工工业出版社,2001年. 被引量:1
  • 2张葆宗主编..反渗透水处理应用技术[M].北京:中国电力出版社,2004:305.
  • 3于丁一,宋澄章,李航宇编著..膜分离工程及典型设计实例[M].北京:化学工业出版社,2005:306.