期刊文献+

可控震源施工中电台数据传输不良的原因分析及排除 被引量:1

Analysis of reasons of bad data transmission in radio transmitter during vibroseis construction and removal of these failures
下载PDF
导出
摘要 可控震源在施工中,常常出现各种电台干扰,导致震源数据传输不正常或震源收不到仪器发出的遥控启动信号,影响正常施工。本文介绍了各种电台干扰引起的故障现象,分析了故障产生的原因,给出了故障的排除方法。 The interferences of various radio transmitters often appear in vibroseis construction, which result in abnormal vibroseis data transmission or failing to receive the remote start signals by seismograph that affects the normal construction. The paper introduced the failure phenomenon caused by the interferences of various radio transmitters, analyzed the reasons the failures produced and gave the approaches of removing failures.
出处 《物探装备》 2006年第B08期50-52,共3页 Equipment for Geophysical Prospecting
关键词 可控震源 电台 数据传输 故障 vibroseis, radio transmitter, data transmission, failure