期刊文献+

毛细管放电装置主开关结构对产生软X射线激光的影响 被引量:6

Influence of the Main-Switch of the Capillary Discharge Setup on Soft X-ray Laser
原文传递
导出
摘要 流过毛细管的电流,将直接影响箍缩过程中等离子体的状态,进而影响软X射线激光的产生。由于主开关的导通电感将影响电流波形,因此提出了使用不同结构的主开关电极来改变毛细管电流波形的方案,以寻找最适合毛细管放电软X射线激光产生的电流波形。实验用三种不同结构的主开关电极,观察了主开关导通电感的改变及其对电流波形的幅值和脉宽的影响。根据导通电感的估算结果,利用脉冲功率理论,计算了电流幅值和脉宽的改变情况,并与实验结果进行了比较。实验观察了电流波形的改变对软X射线激光尖峰信号的影响。实验结果表明,放电间隙为3 cm的圆环-圆盘型主开关最适合软X射线激光的输出。 The current in the capillary can affect the state of the plasma in pinch process and affect the soft X-ray laser. The inductance of the main switch can change the current waveform. Therefore the scheme of changing current waveform is put forward with different main switches to find the best current waveforms, which are fit for soft Xray pumped by capillary discharge. In the experiment, three kinds of main switches are used to observe the effect of inductance on the current duration and amplitude. The inductance of main switch is estimated and the current amplitude and duration are calculated with pulse power theory. The theoretical results are compared with the experimental data. With three different main-switches, the influence of current waveforms on soft X-ray laser spike is observed. The experimental results show that the ring-disk shaped main switch, discharge distance of which is 3 cm, is fit for soft Xray laser best.
出处 《中国激光》 EI CAS CSCD 北大核心 2006年第9期1176-1179,共4页 Chinese Journal of Lasers
基金 国家自然科学基金(60038010) 国家863计划(863-804-7-10)资助项目
关键词 X射线光学 毛细管放电 布鲁姆林(Blumlein)传输线 主开关 X射线激光 X-ray optics capillary discharge Blumlein transmission line main switch X-ray laser
  • 相关文献

参考文献10

  • 1彭惠民,王世绩主编..X射线激光[M].北京:国防工业出版社,1997:555.
  • 2J. J. Rocca, D. C. Beethe, M. C. Marconi. Proposal for soft-X-ray and XUV lasers in capillary discharges [J]. Opt. Lett., 1988, 13(7):565-567. 被引量:1
  • 3J. J. Rocca, V. Shlyaptsev, F. G. Tomasel et al.. Demonstration of a discharge pumped table-top soft-X-ray laser [J]. Phys. Rev. Lett. , 1994, 73(16):2192-2195. 被引量:1
  • 4J. J, Rocca, D. P. Clark, J. L. A. Chilla et al.. Energy extraction and achievement of the saturation limit in a dischargepumped table-top soft X-ray amplifier [J]. Phys. Rev. Lett., 1996, 77(8):1476-1479. 被引量:1
  • 5C. D. Macchietto, B. R. Benware, J. J. Rocca. Generation of millijoule-level soft-X-ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier [J]. Opt. Lett. , 1999, 24(16):1115-1117. 被引量:1
  • 6A. Ben-Kish, R. A. Nemirovsky, M. Shuker el al.. Parametric investigation of capillary discharge experiment for collisional excitation X-ray lasers [C]. SPIE, 1999, 3776:166-174. 被引量:1
  • 7Gohta Niimi, Yasuashi Hayashi, Mitsuo Nakajima et al.. Observation of multi pulse soft X ray lasing in a fast capillary discharge [J]. J. Phys. D: Appl. Phys., 2001, 34:2123-2126. 被引量:1
  • 8栾伯晗,赵永蓬,吴寅初,程元丽,王骐.毛细管放电抽运软X光激光产生条件的实验研究[J].中国激光,2005,32(9):1189-1192. 被引量:8
  • 9王莹编著..高功率脉冲电源[M].北京:原子能出版社,1991:297.
  • 10B. M. Luther, Y. Wang, M. C. Marconi et al.. Guiding of intense laser beam in highly ionized plasma columns generated by a fast capillary discharge [J]. Phys. Rev. Lett., 2004, 92(23) :235002-1-235002-4. 被引量:1

二级参考文献9

  • 1李思宁,程元丽,赵永蓬,王骐.毛细管放电条件下类氖序列原子参量计算与分析[J].光学学报,2004,24(11):1581-1584. 被引量:2
  • 2J. J. Rocca, V. Shlyaptsev, F. G. Tomasel et al..Demonstration of a discharge pumped table-top soft-X-ray laser[J]. Phys. Rev. Lett., 1994, 73(16):2192-2195. 被引量:1
  • 3A. Ben-Kish, R. A. Nemirovsky, M. Shukeretal.. Parametric investigation of capillary discharge experiment for collisional excitation X-ray lasers [C]. SPIE, 1999, 3776:166-174. 被引量:1
  • 4Gohta Niimi, Yasushi Hayashi, Mitsuo Nakajima et al..Observation of multi-pulse soft x-ray lasing in a fast capillary discharge[J]. J. Phys. D.. Appl. Phys., 2001, 34:2123-2126. 被引量:1
  • 5Hiroyuki Daido. Review of soft x-ray laser researches and developments [R]. Rep. Prog. Phys. , 2002, 65:1513-1576. 被引量:1
  • 6J. J. Rocca, D. P. Clark, J. L. A. Chilla et al.. Energy extraction and achievement of the saturation limit in a dischargepumped table-top soft X-ray amplifier[J]. Phys. Rev. Lett. ,1996, 77(8) : 1476- 1479. 被引量:1
  • 7Gohta Niimi. Yasushi Hayashi, Nobuhiro Sakamoto et al..Development and characterization of a low current capillarydischarge for X-ray laser studies[J]. IEEE Transactions on Plasma Science, 2002, 30(2) : 616 -621. 被引量:1
  • 8王骐,刘鹏,赵永蓬,杨大为.毛细管的阻抗特性研究[J].中国激光,2003,30(6):497-500. 被引量:2
  • 9程元丽,赵永蓬,肖亦凡,刘鹏,王骐,杨大为.毛细管快放电中的管壁烧蚀[J].中国激光,2004,31(5):538-542. 被引量:4