摘要 简要介绍了高压超声测试技术中样品组装的设计原则。设计了一套新的样品组装,并测量了纯Al和纯Cu在常温下的等温状态方程。实验结果表明,新的组装能够实现较理想的准静水压加载,同时也能够测试出良好的超声信号。分析了六面顶压机上常温超声测量的主要误差来源。 We introduced briefly the principle of design of sample assembly for ultrasonic measurements at high pressure,and designed a new kind of sample assembly to measure the isothermal compression of Al and Cu at 300K.Ideal quasi-hydrostatic loading was realized,and high-quality ultrasonic signals were obtained under high pressure.It was indicated that the design of sample assembly was reasonable.We analyzed in brief main uncertainty of ultrasonic measurement in six-side anvil cell at 300K.
出处 《高压物理学报》 EI CAS CSCD 北大核心 2006年第3期331-335,共5页 Chinese Journal of High Pressure Physics
关键词 样品组装 超声测试技术 六面顶压机 sample assembly ultrasonic measurement six-side anvil cell
  • 相关文献

参考文献5

  • 1Li B S,Gwanmesia G D,Liebermann R C.Sound Velocities of Olivine and Beta Polymorphs of Mg2SiO4 at Earth's Transition Zone Pressures[J].Geophys Res Lett,1994,23(17):2259-2262. 被引量:1
  • 2Houck J G,Hutton U O.High Pressure Measurement[M].London:Butterworths & Co,1983:221. 被引量:1
  • 3Mao H K,Bell P M.High-Pressure Physics:Sustained Static Generation of 1.33 to 1.72 Megabars[J].Science,1978,200:1145-1147. 被引量:1
  • 4Christensen N I.Fabric,Seismic Anisotropy,and Tectonic History of the Twin Sisters Dunite,Washington[J].Geological Society Am Bull,1997,78:301-317. 被引量:1
  • 5Steven D J,Hartmust S,Hans J R.Shear Waves in the Diamond-Anvil Cell Reveal Pressure-Induced Instability in (Mg,Fe)O[J].PNAS,2004,101:5867-5871. 被引量:1

同被引文献14

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部