离子色谱法中高浓度盐基体对无机阴离子分析影响规律的研究 被引量:5

STUDY OF THE EFFECTS OF LARGE AMOUNTS OF SALTS IN THE SIMULATIVE MATRICES ON ANALYSIS OF VARIOUS INORGANIC ANIONS BY USING ION CHROMATOGRAPHY
下载PDF
导出
摘要 本文首次研究高浓度盐基体中,大量盐的存在对无机阴离子的保留时间、峰高和峰面积等参数的影响规律,并对其影响机理进行了初步探讨.实验证明,在样品中离子总浓度不超过柱容量的情况下,虽然由于某些离子的浓度过高,使待测离子的保留时间变短,峰形改变,但用峰面积和标准加入外推法计算,仍可得到较好的结果. This paper studied the effects of large amounts of salts in the simulative matrices on the retention time, peak height and peak area for analysis of anions by ion chromatogra-phy ,and the mechanism was preliminarily explored. The experiments show that the samples with high concentration of some anions cause a relatively shorter retention time and a changed peak shape, but a better result can be obtainded by measurement of peak area and standard spike.Recoveries of various inorganic anions in tap water were 95. 5%, 96. 8% and 95. 2% for chloride, nitrate and sulfate, respectively.
出处 《环境化学》 CAS CSCD 北大核心 1996年第5期451-456,共6页 Environmental Chemistry
关键词 离子色谱法 高浓度盐基体 阴离子 ion chromatography, matrix, anion.