拉—压预应力混凝土结构

Tension-compression prestressed concrete structures
下载PDF
导出
摘要 提出拉-压预应力混凝土结构定义;根据预压控制应力不大于比例极限,在设计荷载作用下预压钢管应力取值等于强度设计值的原则,确立了预压元件控制应力;根据有关约束条件,推导了预拉应力筋Ap、预压应力筋AT、拉区非预应力筋AS和压区非预应力筋A'S的匹配关系。 The definition of tension-compression prestressed concrete structures was brought.Forms control stress of pre-compression control stress according to principle of control stress value not to exceed proportion stress and pre-compression tube stress equal to the strength,on the basis of relative control condition.discusses the matching of tendon area(AP),ofpre-compression component area(AT).common steel area of tension-section(As),and common steel area of compression section(A's)and presents design process and method of tension-compression prestressed concrete structures.
作者 刘少春
出处 《中外建筑》 2005年第4期121-122,共2页 Chinese & Overseas Architecture
关键词 拉-压预应力 混凝土 控制应力 匹配关系 tension-compression prestress,concrete,control stress:matching