动态三维超声心动图定性、定量诊断复杂型先天性心脏病的研究 被引量:4

Qualitative and quantitative study on complex congenital heart disease with dynamic three dimensional echocardiography
下载PDF
导出
摘要 目的探讨动态三维超声心动图(3DE)诊断复杂型先天性心脏病的应用价值。方法对复杂型先天性心脏病患儿42例应用HP5500型彩色多普勒超声心动图仪采集二维数据,在TOMTEC计算机工作站进行三维重建,然后应用圆盘总和法测量左室舒张末期容积(LVEDV)、收缩末期容积(LVESV)、每搏量(LVSV)及射血分数(EF),同时应用二维超声心动图(2DE)Simpson法测量了上述指标。28例应用心导管检查(Fick)测量了左室每搏量,30例患儿接受手术治疗。结果所有患儿均获得满意的三维图像,能清晰显示心内膜、二尖瓣、三尖瓣及主动脉瓣,准确显示心血管三维空间解剖畸形。应用3DE测得LVEDV、LVESV、LVSV、EF分别为(42·6±8·2)ml、(16·5±3·4)ml、(27·3±7·8)ml、(64·2±6·4)%,与2DEC(Simpson法)的测值相比相关性良好(r值分别为0·85、0·86、0·84及0·82,P均<0·001),2DE测量结果偏低,但两者比较差异无统计学意义(P>0·05)。2DE(Simpson法)所测LVSV与心导管(Fick法)所测结果呈中度相关(r=0·83,P<0·001),而经胸3ED(disk-summation)所测LVSV与心导管检查所测结果呈高度相关(r=0·95,P<0·001)。结论2DE、3DE均可用于检测复杂型先天性心脏病,后者比前者能提供更丰富的诊断信息,测量结果更准确。 Objective To evaluate the three dimensional echocardiography clinical value on diagnosing complex congenital heart diseases.Methods Two dimensional data were studied using HP 5500 color Doppler ultrasound scanner in 42 children with complex congenital heart diseases.Three dimensional echocardiography(3DE) was performed at TOMTEC station.Then the left ventricular end-systolic volume(LVEDV) and end-diastolic volume(LVESV) were measured in these cases from each three dimensional echocardiographic data set with the "disk summation" method. Stroke volume(LVSV) and ejection fracfion(LVEF) were then derived. AU above data were also measured using Simpson method from two dimensional echocardiography(2DE) .The LVSV was also measured using Fick method from cardiac catheterization in 28 cases.30 cases underwent surgical repair. Results Satisfactory 3DE imaging were acquired in all patients to deafly display endocardium, mitral valve, tricuspid valve, aortic valve and the cardiovascular three dimensional anatomic malformation. 3DE provided more abundant diagnosing information than 2DE.The LVEDV,LVESV,LVSV and LVEF from 3DE were(42.6±8.2)ml,(16.5±3.4)m1,(27.3 ±7.8)m1,(64.2 ± 6.4) %, respeetivdy, which showed excellent correlation with those measured with Simpson method( r = 0.85,0.86,0.84 and 0.82, respectively, P 〈 0.001, respectively ). The results from 2DE were lower than that from 3DE but with no significant differences between them ( P 〉 0.05). There were closer limits of agreement between 3DE and Fick for LVSV( r = 0.95) than that between 2DE echocardiography and Fick( r = 0.83). Condusion 2DE and 3DE can be used to evaluate complex congenital heart disease. 3DE can provide abundant diagnosing information and is highly reliable in measuring.
出处 《广西医学》 CAS 2006年第7期974-976,共3页 Guangxi Medical Journal
基金 广西壮族自治区教育厅科研项目(桂科教研〔2002〕316号)。
关键词 超声心动图 三维超声心动图 先天性心脏畸形 Eehogardiogram three dimension congenital heart malformation
  • 相关文献

参考文献11

  • 1Wang-XF, LI-ZA, Cheng-TO, et al. Four dimensional echocardiography:methods and clinical application[J]. Am Heart J, 1996, 132(3):672-684. 被引量:1
  • 2Pandian NG, Roelant JR, Nanda NV, et al, Dynamic three-dimensional echocardiography: method and clinical potential [ J ]. Echocardiography, 1994,11(5):237 被引量:1
  • 3Tantengco MV, Bates JR, Ryan T, et al. Dynamic three dimensional echocardigraphic reconstruction of congenital cardiac septation defects[J]. Pediatr-cardiol, 1997,18(3) : 184 - 190. 被引量:1
  • 4Kardon RE,Cao QL, Masani N, et al. New insights and observations in dimensional echocardiographic visualization of ventricular septal defects: experimental and clinical studies [ J ]. Circulation, 1998,98 ( 13 ) :1307-1314. 被引量:1
  • 5Yao J, Kasprzak JD, Nosir YF, et al. Appropriate 3-dimensional echocardiography data acquisition interval for left ventricle volume quantification: implications for clinical application[J]. J Am Soc Echocardiogr, 1999, 12(12):1053 - 1057. 被引量:1
  • 6Martin RW, Bashein G, Nessly M,et al. Methodology for three dimensional reconstruction of the left ventricle from transesophageal echocardiograms[J]. Ultrasound Med Biol, 1993,19( 1 ) : 27 - 38. 被引量:1
  • 7Kuhl HP,Fmnke A, Merx M,et al. Rapid quantification of left ventricular function and mass using transoesophageal three-dimensional echocardiography: validation of a method that uses long-axis cutplanes[J]. Eur J Echocardiogr,2000,1(3) :213 - 221. 被引量:1
  • 8Sapin PM, Schroder KM, Gopal AS, et al. Comparison of two-and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients[J]. J Am Coll Cardiol, 1994,24(4):1254-1259. 被引量:1
  • 9施亚明,杨俊华,周炳元,宋建平,杨向军,刘志华.三维超声心动图测量心肌梗塞后左室容量的实验研究[J].苏州大学学报(医学版),2003,23(2):147-148. 被引量:7
  • 10庞玉生,黄国英,刘豫阳.经胸三维超声心动图测定左室容量及收缩功能的临床应用[J].中国超声诊断杂志,2002,3(3):167-169. 被引量:2

二级参考文献17

  • 1[1]Ertl G, Gaudron P, Eilles C, et al. Serial changes in left ventricular size after acute myocardial infarction[J]. Am J Cardiol,1991,68:116D~120. 被引量:1
  • 2[2]Picard MH, Wilkins GT, Ray PA, et al. Natural history of left ventricular size and function after acute myocardial infarction. Assessment and prediction by echocardiographic endocardial surface mapping[J]. Circulation,1990,82:484~494. 被引量:1
  • 3[3]Byrd BF, Finkbeiner W,Bouchard A,et al. Accuracy and reproducibility of clinically acquired two-dimensional echocardiographic mass measurements[J].Am Heart J,1989,117:133~137. 被引量:1
  • 4[4]Belohlavek M,Foster SM,Kinnick RR,et al.Reference techniques for left ventricular volume measurement by three-dimensional echocardiography:determination of precision,accuracy,and feasibility[J].Echocardiography,1997,14:329~335. 被引量:1
  • 5[5]Jotz RJ,Trabold T,Bock A,et al.In vitro measurement accuracy of three-dimensional ultrasound[J].Echocardiography,2001,18:149~156. 被引量:1
  • 6[6]Hibberd MG,Chuang ML,Beaudin RA,et al.Accuracy of three -dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction[J].Am Heart J,2000,140:469~475. 被引量:1
  • 7Legget ME,Leotta DF,Bolson EL,et al.System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing system.IEEE Trans biomed Eng,1998,45:494~504 被引量:1
  • 8Fazzalari NL,Goldblatt E,Adams AP,et al.A composite three-dimensional echocardiographic technique for left ventricle volume estimation in childrent:comparision with angiography and established echocardiographic method.J Clin Ultrasound,1986,14:663~667 被引量:1
  • 9Nosir YFM,Fioretti PM,Vletter WB,et al.Accurate measurement of left ventricle ejection fraction by three-dimensional echocardiography.Circulation,1996,94:460~466 被引量:1
  • 10Gopal AS,Keller AM,Rigling R,et al.Left ventricular volume and endcardial surface area by three dimensional echocardiography:comparison with two dimensional echocardiography and nuclear magnetic resonance imaging in normal subjects.J AM Coll Cardiol,1993,22:258 被引量:1

共引文献6

同被引文献60

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部