THERMAL BOUNDARY LAYER IN CFB BOILER RISER

THERMAL BOUNDARY LAYER IN CFB BOILER RISER
原文传递
导出
摘要 Measurement of temperature profiles of gas-solid two-phase flow at different heights in commercial-scale circulating fluidized bed (CFB) boilers was carried out. Experimental results showed that the thickness of thermal boundary layer was generally independent of the distance from the air distributor, except when close to the riser outlet. Through analysis of flow and combustion characteristics in the riser, it was found that the main reasons for the phenomena were: 1 ) the hydrodynamic boundary layer was thinner than the thermal layer and hardly changed along the CFB boiler height, and 2) both radial and axial mass and heat exchanges were strong in the CFB boiler. Numerical simulation of gas flow in the outlet zone confirmed that the distribution of the thermal boundary layer was dominated by the flow field characteristics. Measurement of temperature profiles of gas-solid two-phase flow at different heights in commercial-scale circulating fluidized bed (CFB) boilers was carried out. Experimental results showed that the thickness of thermal boundary layer was generally independent of the distance from the air distributor, except when close to the riser outlet. Through analysis of flow and combustion characteristics in the riser, it was found that the main reasons for the phenomena were: 1 ) the hydrodynamic boundary layer was thinner than the thermal layer and hardly changed along the CFB boiler height, and 2) both radial and axial mass and heat exchanges were strong in the CFB boiler. Numerical simulation of gas flow in the outlet zone confirmed that the distribution of the thermal boundary layer was dominated by the flow field characteristics.
出处 《China Particuology》 SCIE EI CAS CSCD 2006年第3期131-135,共5页
关键词 thermal boundary layer fluid-dynamic layer flow field heat transfer thermal boundary layer, fluid-dynamic layer, flow field, heat transfer
  • 相关文献

参考文献2

二级参考文献37

  • 1郑洽余,刘信刚,金燕.循环流化床锅炉燃烧室内焦炭粒子燃烧特性的研究[J].工程热物理学报,1995,16(1):106-110. 被引量:16
  • 2[1]MOE T A, MANN M D, HENDERSON A K,et al. Pilot scale CFBC systems: A valuable tool for design and permitting[A]. In : Avidan A A, ed. Proc 4th Int Conf CFB[C]. USA:Pennsylvania, ASME Press, 1993: 116-122. 被引量:1
  • 3[2]GLICKSMAN L R, HYRE M, WESTPHALEN D. Verification of scaling relations for circulating fluidized beds[A]. In: Rubow L N, Commonwealth G, eds. Proc 4th Int Conf CFB[C].USA: San Diego, ASME Press, 1993: 69-70. 被引量:1
  • 4[3]HORIO M. Hydrodynamics of circulating fluidization: present status and research needs[A]. In: Basu P, Large J F, eds. Proc 1st Int Conf CFB[C].Oxford: Pergamon Press, 1991:3-14. 被引量:1
  • 5[4]DIET P W. Collection efficiency of cyclone separators[J]. AIChE, 1981,27(6):125-176. 被引量:1
  • 6[6]BURSI J M, LAFANECHERE L, JESTIN L. Basic design studies for a 600 MW FBC boiler (270 b, 2×600 ℃)[A]. In:Robert B R, ed. Proc of the 15th Int Conf CFB[C], Georgia:Savannah, 1999:16-19. 被引量:1
  • 7[7]ZHANG JIANSHENG, LU JUNFU, YUE GUANGXI, et al. Inverstigation on the circulating fluidized bed boiler Design[A]. Proc of CCC on Boiler Technology[C],Beijing:2002:34-37. 被引量:1
  • 8[8]KEFER V. Critical heat flux (CHF)and post-CHF heat transfer in horizontal and inclined evaporator tubes[J].Int J Multiphase Flow, 1989, 15(3):385-392. 被引量:1
  • 9[9]SKOWYRA R S, CZARNECKI T S, SUN C Y,et al. Design of a supercritical sliding pressure circulating bed boiler with vertical water walls[A]. In: Rubow L N ed. Proc 13th Int Conf on FBC[C], New York: ASME Press,1995:17-25. 被引量:1
  • 10[11]JIN X,LU J, ZHANG J. Experimental investgation on heat transfer in industrial-scale circulating fluidized bed boilers[A]. In: Werther J ed. Proc 6th Int Conf of CFB[C]. New York:ASME, 1999:356-361. 被引量:1