期刊文献+

计算机导航辅助下全膝关节置换术临床分析 被引量:3

Computer-assisted navigation for total knee arthroplasty
下载PDF
导出
摘要 目的评价计算机导航辅助在全膝关节置换术中的作用。方法对10例骨性关节炎患者的11个膝关节在计算机导航辅助下完成全膝关节置换术。结果术后出血量明显减少,术后3个月关节活动度平均屈曲115°。HSS改良评分术前平均43分,术后平均90分。结论计算机导航辅助能精确地控制假体选择、截骨量、假体角度,对软组织松解和平衡可以实行量化操作,对全膝关节置换术有良好的辅助作用。 Objective To evaluate the use of computer- assisted navigation for total knee arthroplasty (TKA). Methods From December 2004 to November 2005, 13 total knee prostheses were implanted with a computer- assisted navigation systom (Brian - Lab, Germany). The Clinical results were studied and analyzed. Results All of the femoral and tibial components were put in satisfactory positions. The time of operation was decreasing with the doctor's proficiency at this technique. The post - operative drainage was decreased obviously than after traditional TKA. A clinical check - up 3 months after operation revealed the average mobility (ROM) was 115°, with no abnormal laxity in the operated knee. Conclusion The contribution of the computer- assisted navigation in TKA is approvable.
出处 《徐州医学院学报》 CAS 2006年第4期335-337,共3页 Acta Academiae Medicinae Xuzhou
关键词 全膝关节置换术 计算机辅助 导航 total knee arthroplasty computer- assisted navigation
  • 相关文献

参考文献5

二级参考文献18

  • 1罗毅,刘允才.机器人全膝关节置换术中股骨头中心的求法[J].中国医疗器械杂志,2004,28(4):239-241. 被引量:3
  • 2郭开今,程兆明,李磊,周冰,郭含军,汪礼文.膝关节置换术中胫骨假体点、线、面放置与术后膝关节功能恢复的关系(英文)[J].中国临床康复,2005,9(2):220-222. 被引量:4
  • 3Jast M, Maloney WJ, Bradon CR, et al. Histomorphological studies of the longterm skeletal responses to well fixed cemented femoral components. J Bone Joint Surg(Am) 1990; 72 ( 1 ) : 220 - 3. 被引量:1
  • 4Garg A, Walker PS. Prediction of total knee motion using a three-dimensional computer-graphics model. J Biomech 1990:23 ( 1 ) : 45 - 51. 被引量:1
  • 5Front-Rodriguez DE, Scuderi GR, Insall JN. Surviorship of cemented total knee arthroplasty. Clin Orthop 1997 ; ( 345 ) : 79 - 86. 被引量:1
  • 6Rodriguez JA, Bhende H, Ranawat CS. Total condylar knee replacement: a 20-year follow-up study. Clin Orthop 2001 ; (388 ) : 10 - 7. 被引量:1
  • 7Sharkey PF, Hozack WJ, Rothman RH, et al. Why are total knee arthroplasties failing today. Clin Orthop 2002; (404): 7 - 13. 被引量:1
  • 8Rand JA. Cement or cementless fixation in total knee arthroplasty. Clin Orthop1991; 273:52 - 6. 被引量:1
  • 9Bryan RS, Rand JA. Revision total knee arthroplasty. Clin Orthop 1982: ( 170):116. 被引量:1
  • 10Ewald FC, Jacobs MA, Miegel RE, et al. Kinematic total knee replacement. J Bone Joint Surg(Am) 1984; 66(7): 1032 - 7. 被引量:1

共引文献6

同被引文献17

引证文献3

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部