摘要
A novel tetraiodocadmate(Ⅱ)-selective membrane electrode consisting of tetraiodo-cadmate(Ⅱ)-rhodamin B ion pair (TICRhB) dispersed in a PVC matrix plasticized with 2-nitrophenyl octyl ether (o-NPOE) was prepared. The sensor demonstrated a near-Nernstian response for 1×10^-2 to 2×10^-6 mol/L cadmium (Ⅱ) at 25℃ with an anionic slope of 29.0. It revealed very good selectivity for Cd^2+ with negligible interference from many cations and anions, and could be used in a pH range of 3 to 6.
A novel tetraiodocadmate(Ⅱ)-selective membrane electrode consisting of tetraiodo-cadmate(Ⅱ)-rhodamin B ion pair (TICRhB) dispersed in a PVC matrix plasticized with 2-nitrophenyl octyl ether (o-NPOE) was prepared. The sensor demonstrated a near-Nernstian response for 1×10^-2 to 2×10^-6 mol/L cadmium (Ⅱ) at 25℃ with an anionic slope of 29.0. It revealed very good selectivity for Cd^2+ with negligible interference from many cations and anions, and could be used in a pH range of 3 to 6.
基金
Thanks for the financial support of the Natural Science Foundation of Chongqing City (No. CSTC-2005 BB4100)
the Southwest University Foundation (XSGX02) for the present work.