期刊文献+

弱酸树脂处理“负硬水” 被引量:1

Treatment of "negetive hard water" by using weak acidic resin
下载PDF
导出
摘要 用H+柱—脱气塔—Na+柱串联工艺处理“负硬水”。H+柱浮动床,Na+柱固定床,均采用弱酸性阳离子交换树脂110。处理后的水在满足硬度要求的同时,碱度<1.0 mmol/L,出水体积可高达H+交换柱树脂体积的260倍以上。运行结果表明,工艺具有操作简便、出水稳定、水质良好等优点,是处理“负硬水”非常好的方法。 The "negative hard water" is treated by consecutive H^+ ion exchange, degasification, and Na^+ ion exchange procedures. The H^+ion exchange column is a fluidized bed and the Na^+ ion exchange column is a fixed bed. In both columns the weak acidic ion exchange resin 110 is used as the packings. The alkality of the treated water is less than 1.0 mmol/L under the required hardness, and the volume of produced water is as high as 260 times of that in a single H^+ ion exchange resin column. It is shown that the proposed technology has the advantages of simple operation, stable water production, and high quality of produced water.
出处 《工业水处理》 CAS CSCD 北大核心 2006年第6期87-89,共3页 Industrial Water Treatment
关键词 弱酸性树脂 水处理 软化 负硬水 weak acidic resin water treatment softening negetive hard water
  • 相关文献

参考文献7

  • 1姚继贤主编..工业锅炉水处理及水质分析[M].北京:劳动人事出版社,1987:538.
  • 2吴桂英.高碱性水质的锅外化学处理[J].工业水处理,1997,17(1):44-44. 被引量:2
  • 3陈志和,王宜昌.氯离子交换脱碱水处理的试验研究[J].工业水处理,1992,12(1):29-31. 被引量:3
  • 4华东建筑设计院.给水排水设计手册,第4册,工业给水处理[M].北京:中国建筑工业出版社,1989:45, 被引量:1
  • 5李培元编..低压锅炉水质处理[M],1984:272.
  • 6卢宗义.软水碱度计算和调节[J].工业水处理,1992,12(4):37-38. 被引量:1
  • 7金熙等编..工业水处理技术问答及常用数据 第2版[M].北京:化学工业出版社,1997:919.

共引文献3