摘要 对配置切向燃烧一次风反切系统的煤粉炉水冷壁结焦事故的分析,指出防止炉膛结焦的重要措施是防止炉内气流发生旋转方向的改变。 Slagging incidencesin of water - cooled wall in pulverized coal fired boiler, which was configured tangential combustion primary air to system of cutting on the contrary was analysed herein Measures of preventing slagging was put foruard as well, which is avoiding change of gas flow direction.
出处 《锅炉制造》 2006年第3期13-15,共3页 Boiler Manufacturing
关键词 直流锅炉 反切 结焦 once through boiler cut on the contrary slagging