摘要
介绍了1次作为真空容器的凝汽器的水位测量偏差缺陷消除的过程。由于常规的消缺办法无法奏效,通过观察总结出隐含规律,并依据理论分析和公式计算找出故障范围和原因,在不影响机组安全运行的基础上消除了缺陷。
The process of eliminating the measurement errors for the water level of the vacuum container of condenser is presented. Since conventional approaches were ineffectual, theoretical analysis and calculation were, applied to find out the fault area and the reasons, and the fault was eliminated without affecting the safe operation of thc unit.
出处
《华东电力》
北大核心
2006年第6期81-82,共2页
East China Electric Power
关键词
真空容器
水位测量
泄漏
堵塞
vacuum container
water level measurement
leakage
blockage