摘要 提出一种用于带电测量输电线路互感参数的新方法。该方法采用全球卫星定位系统(GPS)送出的时间同步信号作为各测量点的同步采样基准,解决了不同端线路互感参数带电测量的同时性问题。文中对该方法进行了理论上的分析,对用于带电测量互感的计算机系统的硬件组成进行了介绍。 A new method of mutual inductance measurement for multicircuit non conterminous H V transmission lines (MNTL) is presented.This method is able to synchronize the samplings of voltage phasor measurement at an accuracy within 1μsec at two or more remote substation,by means of the global positioning system(GPS),which solve the simultaneous problem of mutual inductance measurement for MNTL.The mutual inductance algorithm is deduced and the main components of measurement system is introduced in this paper.This system has been put into practical use in measurement of a 220kV power network near WuHan,HuBei province,China.
出处 《广东机械学院学报》 1996年第3期16-22,共7页 Industrial Engineering Journal
关键词 同步采样 高压 输电线路 带电测量 GPS synchronized sample multicircuit non cotermintal transmission lines(MNTL) mutual inductance electrified measurement global positioning system(GPS)