期刊文献+

电话传输心电图与动态心电图临床应用比较 被引量:1

Comparison of Transtelephonic Electrocardiographic Monitoring and Dynamic Electrocardiogram in Clinical Application
下载PDF
导出
摘要 【目的】比较电话传输心电图(TTM)与动态心电图(DCG)对心律失常、心肌缺血的检出率,比较两者在临床应用上的优缺点,为临床合理使用TTM提供指导。【方法】采取自身对照,对比分析80例因心悸、胸闷、胸痛等不适住院患者的TTM及DCG检出结果。【结果】①TTM对偶发房性早搏、偶发室性早搏及ST-T改变的检出率比DCG高(P<0.05);②TTM对频发房性早搏、频发室性早搏、短阵房性心动过速、阵发性心房颤动、短阵室性心动过速、高度房室传导阻滞的检出率与DCG差异无显著性(P>0.05);③TTM可随时随地将病人的心电信息发送到医院监护中心,及时对所发生的心血管事件进行处理;④少数TTM图形欠清晰,自动化分析结果有偏差,需通过人工分析补充完善。【结论】TTM对发作无规律、间歇发作、持续时间短暂的心律失常及一过性心肌缺血有独到价值,非常适合心律失常、心肌缺血突发事件高危人群的院外监护。 [Objective]To compare the detection rates of transtelephonic electrocardiographic monitoring (TTM) and dynamic electrocardiogram(DCG) in arrhythmia and myocardial ischemia, to compare their merits and shortcomings in clinical application and to provide direction for using TTM reasonably in clinic. [Methods] TTM and DCG were used and compared on 80 patients in hospital because of palpitaion,chest distress, pectoralgia. [Resuhs]①The detection rates of accidental atrial, ventricular premature beats and the change of ST-T segments were higher by TTM than by DCG for most cardiac events( P 〈0.05) ;②There were no significantly statistic differences between the detection rates of frequent atrial,ventricular premature beats, paroxysmal atrial fibrillation,paroxysmal ventricular tachycardia,high atrioventricular block and paroxysmal atrial tachycardia( P 〉0.05);③TTM could send the patients electrocardiogram information to the custody centers of hospitals any time and anywhere so as to handle cardiovascular events in time;④)A few delineation of TTM wasn't quite clear-cut, automatic analysis was not very accurate, manpower analysis to supplement was needed. [Conclusion]TTM has independent value for irregular,intermittent, momentary arrhythmia and myocardial ischemia , it is very perfect for controlling high risk out patients of arrhythmia and myocardial ischemia for sudden cardiac events.
机构地区 解放军第
出处 《医学临床研究》 CAS 2006年第6期831-833,共3页 Journal of Clinical Research
关键词 I心电描记术 心电描记术 便携式 电话 electrocardiography electrocardiography,ambulatory telephone
  • 相关文献

参考文献8

  • 1孟繁华.电话传输心电图监测系统的应用与进展[J].国外医学(心血管疾病分册),1996,23(5):281-283. 被引量:13
  • 2黄晓明,庞振瑶,黄群英,梁凌,蒋小菊,刘卫华.电话传送心电图监测与常规心电图诊断心肌缺血的应用比较[J].广西医科大学学报,2000,17(2):268-269. 被引量:6
  • 3Scalvini S, Zanelli E, Gazzaniga P, et al . Telemedicine: Utility for care and monitoring in ischemic cardiac disease [J].Computers in Cardiology , 1999,26 :409-412. 被引量:1
  • 4Scalvini S, Zanelli E, Martinelli G, et al . Cardiac event recorder yields more diagnoses than 24-hour Hoher monitoring in patients with palpitations[J]. Ital Heart J Suppl ,2004,5(3) :186-191. 被引量:1
  • 5Saarel EV. Stefanelli CB, Fischbach PS, et al. Transtelephonic electrocardiographic monitors for evaluation of children and adolescents with stspected arrhythmias[J]. Pediatrics,2004,113(2) :248-251. 被引量:1
  • 6Senatore G, Stabile G, Bertaglia E, et al . Role of transtelephonic electrocardiographic monitoring in detecting short-term arrhythmia recurrences after radiofrequency ablation in patients with atrial fibrillation[J]. J Am Coll Cardial . 2005,45 (6) :873-876. 被引量:1
  • 7Mischke K, Zarse M, Perkuhn M, et al . Telephonic transmission of 12-lead electrocardiograms during acute myocardial infarction[J]. J Telemed Telecare ,2005,11(4) : 185-190. 被引量:1
  • 8陈焕芹,常静,高海青,侯盛华.比较电话遥控心电图与动态心电图对心律失常的检出率[J].中国循环杂志,2005,20(5):353-355. 被引量:8

二级参考文献8

  • 1姚恩达,王晋生,陈红,陈秋玉,吕心阳.心电电话监测、普通心电图、动态心电图应用比较(附209例分析)[J].福建医药杂志,1996,18(3):29-30. 被引量:6
  • 2Harrison DC,Fitzgerald JW,Winkle RA.Ambulatory electrocardiography for diagnosis and treatment of cardiac arrhythmias.N Engl J Med,1976,294:373-378. 被引量:1
  • 3Kennedy HL,Caralis DG. Ambulatory electrocardiography.Ann Intern Med,1977,87:729-735. 被引量:1
  • 4Grodman RS,Capone RJ,Most AS.Arrhythmia surveillance by transtelephonic monitoring:Comparison with Holter monitoring in symptomatic ambulatory patients.American Heart Journal,1979,98(4):459-464. 被引量:1
  • 5Zimetbaum PJ,Kim KY,Josephson ME,et al.Diagnostic yield and optimal duration of continuous-loop event monitoring for the diagnosis of palpitations:A cost-effectiveness analysis.Ann Intern Med, 1998, 128(11):890-895. 被引量:1
  • 6Scalvini S,Zanelli E,Gazzaniga P,et al.Telemedicine:Utility for care and monitoring in ischemic cardiac disease.Computers in Cardiology,1999,26:409-412. 被引量:1
  • 7Scalvini S, Zanelli E, Martinelli G, et al. Cardiac event recorder yields more diagnoses than 24-hour Holter monitoring in patients with palpitations. Ital Heart J Suppl. 2004,5(3):186-191. 被引量:1
  • 8Saarel EV, Stefanelli CB, Fischbach PS, et al. Transtelephonic electrocardiographic monitors for evaluation of children and adolescents with suspected arrhythmias. Pediatrics,2004,113(2):248-251. 被引量:1